N2300 Trace Detector
The N2200 narcotics trace detector pinpoints minute traces of cocaine, opiates, cannabis, hashish, methamphetamine, and other amphetamine-type stimulants.
Availability: Commercially Available
Manufacturer |
| Scintrex Trace Corp. (division of Autoclear) |
Product Name |
| N2300 Trace Detector |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Spectrometry; |
Detection Method |
| Ion Mobility Spectrometry; |
Application |
| Trace Analysis;Screening;Forensics; |
Equipment Type |
| Instrument |
Product Synopsis |
| The N2200 narcotics trace detector pinpoints minute traces of cocaine, opiates, cannabis, hashish, methamphetamine, and other amphetamine-type stimulants. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
Market Entry Date |
| 2005 |
User Feedback Sources |
| Indifferent/No user feedback |
Supporting Documentation |
| Docs: Scintrex - N2200 Trace Detector.pdf; |
Dimensions |
| 17.6 x 7.4 x 6.2 in (44.9 x 18.9 x 15.8 cm) |
Weight |
| <30 Lbs.; 7 Lbs. (3.2 kg) |
Power Requirements |
| Lithium Battery; AC/DC Line Power; 12 VDC rechargeable battery; 12 VAC adapter; 90 to 264 VAC, 50 to 60 Hz universal switching (Imput voltage) |
Transportability |
| Handheld |
Ruggedness |
| Vibration/Shock; In house vibration tested. |
Operating Conditions |
| 0 to 55°C (32 to 131°F) |
Consumables |
| None |
Calibration Schedule |
| Self cleaning "bake-off" function |
Available Accessories |
| External battery, printer, reusable metal swabs |
Data Analysis Support Equipment |
| PC, software |
Communications Interface |
| RS-232 serial output |
Expected Operational Life |
| > 7 years |
Shelf Life |
| >5 years |
Tested For Explosives |
| TNT, RDX, NG, AN, PETN, EGDN, HMX
and UN |
Tested For Narcotics |
| Cocaine, opiates, THC, heroin, amphetamine-type stimulants, fentanyl, carfentanil, sufentanil, alfentanil, remifentanil, ketamine, lorazepam, 3-quinuclidinyl benzilate, U-47700 |
Adaptability |
| Yes; manufacturer can add new targets to detector |
Sample Introduction |
| Vapor/Gas; |
Sensitivity/Detection Limits |
| ng |
Start Up Time (From Cold Start To Sample Ready) |
| 20 minutes |
Response Time (Sample Application To Output) |
| <1 minute; < 40 seconds |
Total Run Time |
| Seconds |
Alarm Capability |
| Audible and visual |
Software Control |
| On-board, PC |
Other Operational Parameters |
| Surface ionization detection, 1,000 retrievable data records. No radioactive source. |
Training Required |
| <1 day training |
Training Available |
| Yes |
Manuals Available |
| Yes |
Warranties |
| 1 year |
IATA Shipping Restrictions |
| No |