N2300 Trace Detector

The N2200 narcotics trace detector pinpoints minute traces of cocaine, opiates, cannabis, hashish, methamphetamine, and other amphetamine-type stimulants.

Notify me on updates of this product 

Availability: Commercially Available

Dao Hinh Nguyen, Ph.D.
VP Engineering and Product Development
daon@autoclear.com
+1 613 224 1061 ext. 230
2 Gardner Road
Fairfield, NJ 07004
USA
www.autoclear.com
Manufacturer
Scintrex Trace Corp. (division of Autoclear)
Product Name
N2300 Trace Detector
Detection Category
Chemical; Explosives
Detection Principle
Spectrometry;
Detection Method
Ion Mobility Spectrometry;
Application
Trace Analysis;Screening;Forensics;
Equipment Type
Instrument
Product Synopsis
The N2200 narcotics trace detector pinpoints minute traces of cocaine, opiates, cannabis, hashish, methamphetamine, and other amphetamine-type stimulants.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Market Entry Date
2005
User Feedback Sources
Indifferent/No user feedback
Supporting Documentation
Docs: Scintrex - N2200 Trace Detector.pdf;
Dimensions
17.6 x 7.4 x 6.2 in (44.9 x 18.9 x 15.8 cm)
Weight
<30 Lbs.; 7 Lbs. (3.2 kg)
Power Requirements
Lithium Battery; AC/DC Line Power; 12 VDC rechargeable battery; 12 VAC adapter; 90 to 264 VAC, 50 to 60 Hz universal switching (Imput voltage)
Transportability
Handheld
Ruggedness
Vibration/Shock; In house vibration tested.
Operating Conditions
0 to 55°C (32 to 131°F)
Consumables
None
Calibration Schedule
Self cleaning "bake-off" function
Available Accessories
External battery, printer, reusable metal swabs
Data Analysis Support Equipment
PC, software
Communications Interface
RS-232 serial output
Expected Operational Life
> 7 years
Shelf Life
>5 years
Tested For Explosives
TNT, RDX, NG, AN, PETN, EGDN, HMX and UN
Tested For Narcotics
Cocaine, opiates, THC, heroin, amphetamine-type stimulants, fentanyl, carfentanil, sufentanil, alfentanil, remifentanil, ketamine, lorazepam, 3-quinuclidinyl benzilate, U-47700
Adaptability
Yes; manufacturer can add new targets to detector
Sample Introduction
Vapor/Gas;
Sensitivity/Detection Limits
ng
Start Up Time (From Cold Start To Sample Ready)
20 minutes
Response Time (Sample Application To Output)
<1 minute; < 40 seconds
Total Run Time
Seconds
Alarm Capability
Audible and visual
Software Control
On-board, PC
Other Operational Parameters
Surface ionization detection, 1,000 retrievable data records. No radioactive source.
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Warranties
1 year
IATA Shipping Restrictions
No
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: