Radius® BZ1

The Radius® BZ1 is an area monitor that can communicate with Ventis® Pro Series personal monitors. The Radius® BZ1 can detect up to seven gases using 15 sensor options including PID. It has an operational time of 7 days (168 hours) of continuous use. Ability to customize alarm action messages such as "EVACUATE" or "VENTILATE". DualSense® Technology uses two sensors to detect the same gas.

Notify me on updates of this product 

Availability: Commercially Available

+1 412 788 4353
1001 Oakdale Road
Oakdale, PA 15071
USA
www.indsci.com
Manufacturer
Industrial Scientific Corporation
Product Name
Radius® BZ1
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Photoionization Detection;Electrochemical Detection;
Application
Gas Analysis;
Equipment Type
Instrument
Product Synopsis
The Radius® BZ1 is an area monitor that can communicate with Ventis® Pro Series personal monitors. The Radius® BZ1 can detect up to seven gases using 15 sensor options including PID. It has an operational time of 7 days (168 hours) of continuous use. Ability to customize alarm action messages such as "EVACUATE" or "VENTILATE". DualSense® Technology uses two sensors to detect the same gas.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
29 x 29 x 55 cm (11.5 x 11.5 x 21.5 in)
Weight
<30 lbs.; 7.5 kg (16.5 lb)
Power Requirements
NiMH Battery; Rechargeable battery pack
Noise Produced
108 dB at 1 m
Transportability
Person-Portable
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP66, Impact-resistant polycarbonate alloys
Operating Conditions
-20 to 55 °C (-4 to 131 °F), 15 to 95% RH non-condensing (continuous)
Consumables
None
Available Accessories
Optional integral pump, up to 30.48 m (100 ft) sample draw
Communications Interface
Wi-Fi
Expected Operational Life
Indefinite
Shelf Life
>5 years
Tested For ITF-25 TIC/TIMs
VOCs, Ammonia, Carbon monoxide, chlorine, hydrogen, hydrogen sulfide, hydrogen cyanide, nitrogen dioxide, oxygen, sulfur dioxide
Sample Introduction
Vapor/Gas;
Sensitivity/Detection Limits
%; ppm; 0 to 2,000 ppm
Start Up Time (From Cold Start To Sample Ready)
< 5 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous
Alarm Capability
Audible and visual
Software Control
Remote
Other Operational Parameters
Data logging > 3 months at 10-second intervals.
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Warranties
Two-year, including sensors and battery