MiniDOSE

The MiniDOSE personal radiation dosimeter provides everyday protection for workers at risk of exposure to radiation from gamma and X-rays. The datalog enables users to know their exposure on a daily, weekly, monthly, or annual basis, plus they can set alarms to warn about exposure levels or exposure rates. Data can also be transferred to a PC using the included micro-USB connector and software.

Notify me on updates of this product 

Availability: DISCONTINUED

Tom Kochevar
detectgas@honeywell.com
+1 877 723 2878
3775 North First Street
San Jose, CA 65134
USA
www.honeywellanalytics.com
Manufacturer
Honeywell Analytics
Product Name
MiniDOSE
Detection Category
Radiological/Nuclear
Detection Principle
Scintillation Detectors;
Detection Method
Scintillation Detectors;
Application
Personal Radiation Detectors;
Equipment Type
Instrument
Product Synopsis
The MiniDOSE personal radiation dosimeter provides everyday protection for workers at risk of exposure to radiation from gamma and X-rays. The datalog enables users to know their exposure on a daily, weekly, monthly, or annual basis, plus they can set alarms to warn about exposure levels or exposure rates. Data can also be transferred to a PC using the included micro-USB connector and software.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
2.7 x 2.2 x 1.2 in (6.8 x 5.7 x 3.1 cm)
Weight
<1 Lb.; 2.3 oz. (65g)
Power Requirements
Alkaline Battery; AAA battery (700 hours)
Noise Produced
65 dB
Transportability
Pocket Size
Ruggedness
Extreme Temperatures/Humidity
Operating Conditions
-20 to 50°C (-4 to 122°F), 0 to 96% RH non-condensing
Consumables
None
Calibration Schedule
Calibration lasts for two years
Available Accessories
Clip, lanyard and protective silicone case
Data Analysis Support Equipment
PC, software
Communications Interface
USB
Expected Operational Life
Indefinite
Shelf Life
>5 years
Radiological Targets
Gamma, X-ray
Sample Introduction
Radioactive Particle
Sensitivity/Detection Limits
µSv; 0.01 µSv to 10 Sv or 1 µrem to 1000 rem
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous
Alarm Capability
Audible and visual
Software Control
PC
Other Operational Parameters
CsI scintillation detector. Energy range 50 keV to 3 MeV
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Warranties
Yes
IATA Shipping Restrictions
No
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: