ToxiRAE 3

The ToxiRAE 3 is a portable single-gas monitor is designed to keep workers safe against the threat of carbon monoxide (CO) and hydrogen sulfide (H2S) and contains a three-electrode sensor.

Notify me on updates of this product 

Availability: Commercially Available

Bill Kimmell
bill@tgtechservices.com
816-524-8100
613 SW 3rd St.
Lee's Summit, MO 64063
USA
https://sps.honeywell.com/us/en/products/safety/gas-and-flame-detection/portables
Manufacturer
Honeywell Analytics
Product Name
ToxiRAE 3
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Electrochemical Detection;
Application
Gas Analysis; Emergency Response; Forensics;
Equipment Type
Instrument
Product Synopsis
The ToxiRAE 3 is a portable single-gas monitor is designed to keep workers safe against the threat of carbon monoxide (CO) and hydrogen sulfide (H2S) and contains a three-electrode sensor.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
3.4 x 2.2 x 0.8 in (8.6 x 5.5 x 2.0 cm)
Weight
<1 Lb.; 3.5 oz. (99.4 g)
Power Requirements
Lithium Battery; User-replaceable 2/3 AA high-capacity lithium
Noise Produced
95 dB
Transportability
Handheld
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP65
Operating Conditions
-20 to 60°C (-4 to 140°F), 0 to 95% RH
Consumables
None
Available Accessories
AutoRAE 2 Automatic Test and Calibration System; Multi-unit charging station for up to 5 monitors, Wrist Strap, protective rubber boot
Expected Operational Life
Indefinite
Shelf Life
<1 year
Unit Cost
$200.00
Tested For ITF-25 TIC/TIMs
H2S, CO, O2, NH3, CI2, CIO2, HCN, NO, NO2, PH3, and SO2
Adaptability
No; cannot detect or add new targets
Sample Introduction
Vapor/Gas;
Sensitivity/Detection Limits
ppm; 0.1 ppm
Known Interferents/Inhibitors
Depends on the analyte of interest, see Data sheet for specific chemical sensitivity
Start Up Time (From Cold Start To Sample Ready)
Seconds
Response Time (Sample Application To Output)
Continuous (<30 seconds); < 12 seconds
Total Run Time
Continuous
Alarm Capability
Audible, visual and vibrational
Software Control
On-board
Other Operational Parameters
Event logging of up to 10 events,Intrinsically safe, Field-replaceable filter and battery
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Warranties
2 years on non-consumable components and CO, H2S, and O2 sensors 1 year on all other sensors, battery, and other consumable parts
IATA Shipping Restrictions
Yes; lithium battery
Approved Vendors
Multiple