Tetra 3

Handheld multigas detector using 3 simultaneous sensors. Gases include carbon monoxide, methane, oxygen and hydrogen sulphide, ammonia, ozone, sulphur dioxide, H2 filtered CO (for steel plants) and IR carbon dioxide (for safe area use only).

Notify me on updates of this product 

Availability: Commercially Available

sales@crowcon.com
+1 800 527 6926
1455 Jamike Avenue, Suite 100
Erlanger, KY, 41018
USA
www.crowcon.com
Manufacturer
Crowcon Detection Instruments
Product Name
Tetra 3
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Electrochemical Detection;
Application
Gas Analysis;Emergency Response;
Equipment Type
Instrument
Product Synopsis
Handheld multigas detector using 3 simultaneous sensors. Gases include carbon monoxide, methane, oxygen and hydrogen sulphide, ammonia, ozone, sulphur dioxide, H2 filtered CO (for steel plants) and IR carbon dioxide (for safe area use only).
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
4.5 x 2.8 x 1.9 in (11.4 x 7.1 x 4.8 cm)
Weight
<1 lb.; 10.4oz (295g)
Power Requirements
Lithium Battery; Rechargeable
Noise Produced
95 dB
Transportability
Handheld
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; Vibration/Shock; IP65 and IP67, can be submerged.
Operating Conditions
-20 to 55°C (-4 to 131°F), 20 to 90% RH at 40°C non-condensing
Consumables
None
Calibration Schedule
Can be routinely calibrated using Portables PC software or Crowcon Checkbox IMH
Available Accessories
Universal charger, wall mount, shoulder strap, 5 way charger, harness plate, leather carrying case, hard shell case, dust filter
Communications Interface
RS232 connection from interface module in charger, RS232/USB converter available
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$1,100.00
Other Chemical Targets
Carbon monoxide, methane, oxygen, hydrogen sulphide, ammonia, ozone, sulphur dioxide, hydrogen, carbon dioxide
Sample Introduction
Vapor/Gas;
Sensitivity/Detection Limits
ppm
Start Up Time (From Cold Start To Sample Ready)
Seconds
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous
Alarm Capability
Audible, visual, and vibration
Other Operational Parameters
Timed: 50 hours at 1-minute data rate (>12,000 data logs of 4 channels)
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Warranties
Yes
IATA Shipping Restrictions
Yes; Lithium ion battery
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: