Tango TX1

The Tango TX1 multigas electrochemical sensor handheld device uses DualSense® Technology using two sensors to detect the same gas. Sensors include CO, CO/H2, H2S, NO2, and SO2.

Notify me on updates of this product 

Availability: Commercially Available

info@indsci.com
+1 412 788 4353
1001 Oakdale Road
Oakdale, PA 15071
USA
www.indsci.com/tango
Manufacturer
Industrial Scientific Corporation
Product Name
Tango TX1
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Electrochemical Detection;
Application
Emergency Response;Screening;
Equipment Type
Instrument
Product Synopsis
The Tango TX1 multigas electrochemical sensor handheld device uses DualSense® Technology using two sensors to detect the same gas. Sensors include CO, CO/H2, H2S, NO2, and SO2.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
3.9 x 2.0 x 1.4 in (9.9 x 5.1 x 3.5 cm)
Weight
<1 lb.; 126.0 g (4.4 oz)
Power Requirements
Lithium Battery; Alkaline Battery; 3.6 V Primary lithium-thionyl chloride (Li-SOCl2); 1.5AH, 2/3AA; replaceable; non rechargeable; always on; up to 2-year run time depending on operating conditions
Noise Produced
110 dB alarm
Transportability
Handheld
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP66/67. Case top: Polycarbonate with a protective rubber overmold
Operating Conditions
-40 to 50 °C (-40 to 122 °F), 15 to 95% RH non-condensing
Consumables
<$1,000/year; Sensors
Suggested Routine Maintenance
None
Available Accessories
Dust barrier kit, water barrier kit, belt clip, nameplates, soft nylon case, docking station
Expected Operational Life
Indefinite
Unit Cost
$265.00
Maintenance Cost
None
Tested For Chemical Agents
No
Tested For ITF-25 TIC/TIMs
No
Tested For Explosives
No
Tested For Narcotics
No
Other Chemical Targets
CO, CO/H2, H2S, NO2, SO2
Adaptability
No; cannot detect or add new targets
Sample Introduction
Vapor/Gas;
Sensitivity/Detection Limits
ppm; CO, CO/H2 0 to 1,000 ppm in 1 ppm increments. NO2, SO2 0 to 150 ppm in 0.1 ppm increments. H2S 0 to 500 ppm in 0.1 ppm increments.
Start Up Time (From Cold Start To Sample Ready)
Seconds
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous monitor
Alarm Capability
Audible, visual and vibrational
Software Control
On-board
Other Operational Parameters
Data logging: 3 months at 10-second intervals
Training Required
<1 day training
Manuals Available
Yes
Warranties
Guaranteed for Life™. Warranted for as long as the instrument is supported by Industrial Scientific Corporation (excludes sensors, batteries, and filters). CO and H2S sensors are warranted for three years. All other sensors are warranted for two years.