Gas Detection Tubes

The ampoule is broken and its content is shaken down on the cellulose. Execute a prescribed number of strokes (equivalent air volume), wait the prescribed time, break the second ampoule and shake down its content through the crushed glass on the cellulose. The change of the color of the indication layer is evaluated. If a yellow color appears in the specified time, the atmosphere does not contain CWA; the layer remains unchanged in the opposite case or, as the case may be, the yellow color appears only after a longer time.

Notify me on updates of this product 

Availability: Commercially Available

Josef Orel
Director
orel@oritest.cz
+420 257 311 639
Nábrežní 90/4
150 00 Praha 5
Czech Republic
www.oritest.cz
Manufacturer
ORITEST
Product Name
Gas Detection Tubes
Detection Category
Chemical
Detection Principle
Colorimetric;
Detection Method
Colorimetric;
Application
Emergency Response;
Equipment Type
Instrument
Product Synopsis
The ampoule is broken and its content is shaken down on the cellulose. Execute a prescribed number of strokes (equivalent air volume), wait the prescribed time, break the second ampoule and shake down its content through the crushed glass on the cellulose. The change of the color of the indication layer is evaluated. If a yellow color appears in the specified time, the atmosphere does not contain CWA; the layer remains unchanged in the opposite case or, as the case may be, the yellow color appears only after a longer time.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
0.25 x 4 in (0.6 x 10 cm) cylinder
Weight
<1 lb.; 0.45 kg
Power Requirements
None
Transportability
Pocket Size
Operating Conditions
0 to 40°C (32 to 104°F)
Expected Operational Life
Single use item
Shelf Life
<5 years; >1 year
Unit Cost
$30 - $50 per Box of 10 (Price dependent on type of gas)
Tested For Chemical Agents
GB, GD, VX, GA, GF, GP, CK, AC, HCN, HD, HN, L, BZ, CS, CN, CR, adamsite, phosgene, diphosgene, chlorocyanide
Tested For ITF-25 TIC/TIMs
Chlorine, natrium oxides, sulfur dioxide, sulfide, carbon disulfide, ammonia, formaldehyde, carbon monoxide
Sample Introduction
Vapor/Gas;
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Seconds
Alarm Capability
None; color change
Training Required
<1 hour training
Training Available
No
Manuals Available
Yes
Warranties
No
ITAR/EAR Export Regulations
No
IATA Shipping Restrictions
No