EZRaman-N
Discontinued - The EZRaman-N system features a narrow linewidth frequency stabilized laser, high throughput fiber optics probe, and a spectrograph with TE cooled CCD detector. This system can be used with the RamanReader software and requires minimal maintenance.
Availability: DISCONTINUED
Manufacturer |
| TSI, Inc. |
Product Name |
| EZRaman-N |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Molecular Spectroscopy; |
Detection Method |
| Raman Spectroscopy; |
Application |
| Bulk Analysis;Screening;Forensics; |
Equipment Type |
| Instrument |
Product Synopsis |
| Discontinued - The EZRaman-N system features a narrow linewidth frequency stabilized laser, high throughput fiber optics probe, and a spectrograph with TE cooled CCD detector. This system can be used with the RamanReader software and requires minimal maintenance. |
Availability |
| DISCONTINUED |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Supporting Documentation |
| Docs: MRIGlobal - EZRaman-N.pdf; TSI - EZRaman-N.pdf; |
Dimensions |
| 11.25 x 8.6 x 7 in (28.5 x 21.8 x 18 cm) |
Weight |
| <1 lb.; 0.4 lbs (0.19 kg) |
Power Requirements |
| AC/DC Line Power; 19VDC power supply, 100 to 220 VAC 50/60 Hz input |
Transportability |
| Person-Portable |
Ruggedness |
| None |
Operating Conditions |
| 10 to 40°C (50 to 105°F) |
Consumables |
| <$1,000/year; sample vials |
Available Accessories |
| Microscope adaptor, sample holder |
Data Analysis Support Equipment |
| PC |
Expected Operational Life |
| 10,000 hour laser lifetime |
Shelf Life |
| >5 years |
Unit Cost |
| $20,000.00 |
Tested For Chemical Agents |
| Amenable based on technology |
Tested For ITF-25 TIC/TIMs |
| Amenable based on technology |
Tested For Explosives |
| Amenable based on technology |
Tested For Narcotics |
| Amenable based on technology (fentanyl, carfentanil, sufentanil, alfentanil, remifentanil, heroin, ketamine, lorazepam, 3-quinuclidinyl benzilate, U-47700) |
Other Chemical Targets |
| Amenable based on technology |
Adaptability |
| Yes; user can add new targets in the field |
Sample Introduction |
| Liquid;Solid; |
Sensitivity/Detection Limits |
| % |
Known Interferents/Inhibitors |
| Fluorescence |
Start Up Time (From Cold Start To Sample Ready) |
| Minutes |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Total Run Time |
| Seconds |
Software Control |
| PC |
Other Operational Parameters |
| Laser wavelength: 785 nm |
Training Required |
| <1 day training |
Manuals Available |
| Yes |
Warranties |
| 1 year |
IATA Shipping Restrictions |
| No |
Data File Type Format |
| TXT, SPC, DAT, XLS, BMP |