EZRaman-N

Discontinued - The EZRaman-N system features a narrow linewidth frequency stabilized laser, high throughput fiber optics probe, and a spectrograph with TE cooled CCD detector. This system can be used with the RamanReader software and requires minimal maintenance.

Notify me on updates of this product 

Availability: DISCONTINUED

Amy Bauer, Ph.D.
amy.bauer@tsi.com
+1 800 874 2811
500 Cardigan Road
Shoreview, MN 55126
USA
www.tsi.com
Manufacturer
TSI, Inc.
Product Name
EZRaman-N
Detection Category
Chemical; Explosives
Detection Principle
Molecular Spectroscopy;
Detection Method
Raman Spectroscopy;
Application
Bulk Analysis;Screening;Forensics;
Equipment Type
Instrument
Product Synopsis
Discontinued - The EZRaman-N system features a narrow linewidth frequency stabilized laser, high throughput fiber optics probe, and a spectrograph with TE cooled CCD detector. This system can be used with the RamanReader software and requires minimal maintenance.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Supporting Documentation
Docs: MRIGlobal - EZRaman-N.pdf; TSI - EZRaman-N.pdf;
Dimensions
11.25 x 8.6 x 7 in (28.5 x 21.8 x 18 cm)
Weight
<1 lb.; 0.4 lbs (0.19 kg)
Power Requirements
AC/DC Line Power; 19VDC power supply, 100 to 220 VAC 50/60 Hz input
Transportability
Person-Portable
Ruggedness
None
Operating Conditions
10 to 40°C (50 to 105°F)
Consumables
<$1,000/year; sample vials
Available Accessories
Microscope adaptor, sample holder
Data Analysis Support Equipment
PC
Expected Operational Life
10,000 hour laser lifetime
Shelf Life
>5 years
Unit Cost
$20,000.00
Tested For Chemical Agents
Amenable based on technology
Tested For ITF-25 TIC/TIMs
Amenable based on technology
Tested For Explosives
Amenable based on technology
Tested For Narcotics
Amenable based on technology
(fentanyl, carfentanil, sufentanil, alfentanil, remifentanil, heroin, ketamine, lorazepam, 3-quinuclidinyl benzilate, U-47700)
Other Chemical Targets
Amenable based on technology
Adaptability
Yes; user can add new targets in the field
Sample Introduction
Liquid;Solid;
Sensitivity/Detection Limits
%
Known Interferents/Inhibitors
Fluorescence
Start Up Time (From Cold Start To Sample Ready)
Minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Seconds
Software Control
PC
Other Operational Parameters
Laser wavelength: 785 nm
Training Required
<1 day training
Manuals Available
Yes
Warranties
1 year
IATA Shipping Restrictions
No
Data File Type Format
TXT, SPC, DAT, XLS, BMP
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: