EZRaman-H
The EZRaman-H is a handheld Raman analyzer for general purpose, including material identification and verification in a wide variety of applications. The point-and-shoot sampling facilitates verification of a broad range of chemical compounds.
Availability: DISCONTINUED
| Manufacturer |
| TSI, Inc. |
| Product Name |
| EZRaman-H |
| Detection Category |
| Chemical; Explosives |
| Detection Principle |
| Molecular Spectroscopy; |
| Detection Method |
| Raman Spectroscopy; |
| Application |
| Bulk Analysis;Forensics;Emergency Response;Screening; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The EZRaman-H is a handheld Raman analyzer for general purpose, including material identification and verification in a wide variety of applications. The point-and-shoot sampling facilitates verification of a broad range of chemical compounds. |
| Availability |
| DISCONTINUED |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 9.2 x 4 x 8.8 in (23.4 x 10 x 22.4 cm) |
| Weight |
| <5 lbs.; 4.2 lbs (1.9 kg) |
| Power Requirements |
| Lithium Battery; AC/DC Line Power; 110/220 V DC (4 hours) |
| Transportability |
| Handheld |
| Ruggedness |
| None |
| Operating Conditions |
| 10 to 40°C (50 to 104°F) |
| Consumables |
| None |
| Calibration Schedule |
| Automatic |
| Data Analysis Support Equipment |
| RamanReader™ data acquisition and spectra management software; Sample identification with spectral ID or KnowItAll (Optional function) |
| Expected Operational Life |
| 10,000 hour laser lifetime |
| Shelf Life |
| >5 years |
| Unit Cost |
| $33,000.00 |
| Tested For Chemical Agents |
| Amenable by technology |
| Tested For ITF-25 TIC/TIMs |
| Amenable by technology |
| Tested For Explosives |
| Amenable by technology |
| Tested For Narcotics |
| Amenable by technology |
| Adaptability |
| Yes; user can add new targets in the field |
| Sample Introduction |
| Solid;Liquid; |
| Sensitivity/Detection Limits |
| % |
| Known Interferents/Inhibitors |
| Fluoresence |
| Response Time (Sample Application To Output) |
| <5 minutes; 0.2 to 200 seconds, depending on sample |
| Total Run Time |
| Seconds |
| Software Control |
| On-board |
| Other Operational Parameters |
| Laser wavelength: 785nm. 100 to 2700 cm-1 |
| Training Required |
| <1 day training |
| Training Available |
| Yes |
| Manuals Available |
| Yes |
| Warranties |
| Yes |
| IATA Shipping Restrictions |
| Yes; Lithium ion batteries |
| Data File Type Format |
| TXT, SPC, DAT, XLS, BMP |