Nextteq Gas Detection Tubes

The Nextteq gas detection tubes are pre-calibrated, direct-read detector tubes that offer distinct lines of demarcation that require no interpretation, dual scales, concentration charts, or color comparison charts. The tubes are primarily designed to measure the specific gases their tube names imply. Ten tubes are included in each box, unless otherwise noted. Measuring ranges can be obtained by half pump strokes (50 mL), a single full pump (100mL) or multiple full strokes.

Notify me on updates of this product 

Availability: Commercially Available

+1 813 249 5888
8406 Benjamin Road, Suite J
Tampa, FL 33634
USA
www.nextteq.com
Manufacturer
Nextteq LLC
Product Name
Nextteq Gas Detection Tubes
Detection Category
Chemical
Detection Principle
Colorimetric;
Detection Method
Colorimetric;
Application
Gas Analysis;Emergency Response;
Equipment Type
Instrument
Product Synopsis
The Nextteq gas detection tubes are pre-calibrated, direct-read detector tubes that offer distinct lines of demarcation that require no interpretation, dual scales, concentration charts, or color comparison charts. The tubes are primarily designed to measure the specific gases their tube names imply. Ten tubes are included in each box, unless otherwise noted. Measuring ranges can be obtained by half pump strokes (50 mL), a single full pump (100mL) or multiple full strokes.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
0.5 x 4 in (1.3 x 10 cm) cylinder
Weight
<1 lb.; 0.45 kg
Power Requirements
None
Transportability
Pocket Size
Ruggedness
None; Fragile
Operating Conditions
0 to 40°C (32 to 104°F)
Available Accessories
Sampling pump
Expected Operational Life
Single use item
Shelf Life
<1 year
Unit Cost
$70 to $80 per Box of 10
Tested For ITF-25 TIC/TIMs
HCl, Chlorine, HCN, HF, phosphine, phosgene, vinyl chloride, many more
Other Chemical Targets
Acrolein, acetic acid, mercaptans, hydrogen sulfide, limonene, methyl bromide, pyridine, sulfur dioxide, and many more
Sample Introduction
Vapor/Gas;
Sensitivity/Detection Limits
ppm
Start Up Time (From Cold Start To Sample Ready)
Immediate
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Seconds
Training Required
<1 hour training
Training Available
No
Manuals Available
Yes
Warranties
No
IATA Shipping Restrictions
None
Approved Vendors
Fisher, Grainger