Nextteq Gas Detection Tubes
The Nextteq gas detection tubes are pre-calibrated, direct-read detector tubes that offer distinct lines of demarcation that require no interpretation, dual scales, concentration charts, or color comparison charts. The tubes are primarily designed to measure the specific gases their tube names imply. Ten tubes are included in each box, unless otherwise noted. Measuring ranges can be obtained by half pump strokes (50 mL), a single full pump (100mL) or multiple full strokes.
Availability: Commercially Available
+1 813 249 5888
8406 Benjamin Road, Suite J
Tampa, FL 33634
USA
|
|
www.nextteq.com
| Manufacturer |
| Nextteq LLC |
| Product Name |
| Nextteq Gas Detection Tubes |
| Detection Category |
| Chemical |
| Detection Principle |
| Colorimetric; |
| Detection Method |
| Colorimetric; |
| Application |
| Gas Analysis;Emergency Response; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The Nextteq gas detection tubes are pre-calibrated, direct-read detector tubes that offer distinct lines of demarcation that require no interpretation, dual scales, concentration charts, or color comparison charts. The tubes are primarily designed to measure the specific gases their tube names imply. Ten tubes are included in each box, unless otherwise noted. Measuring ranges can be obtained by half pump strokes (50 mL), a single full pump (100mL) or multiple full strokes. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 0.5 x 4 in (1.3 x 10 cm) cylinder |
| Weight |
| <1 lb.; 0.45 kg |
| Power Requirements |
| None |
| Transportability |
| Pocket Size |
| Ruggedness |
| None; Fragile |
| Operating Conditions |
| 0 to 40°C (32 to 104°F) |
| Available Accessories |
| Sampling pump |
| Expected Operational Life |
| Single use item |
| Shelf Life |
| <1 year |
| Unit Cost |
| $70 to $80 per Box of 10 |
| Tested For ITF-25 TIC/TIMs |
| HCl, Chlorine, HCN, HF, phosphine, phosgene, vinyl chloride, many more |
| Other Chemical Targets |
| Acrolein, acetic acid, mercaptans, hydrogen sulfide, limonene, methyl bromide, pyridine, sulfur dioxide, and many more |
| Sample Introduction |
| Vapor/Gas; |
| Sensitivity/Detection Limits |
| ppm |
| Start Up Time (From Cold Start To Sample Ready) |
| Immediate |
| Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
| Total Run Time |
| Seconds |
| Training Required |
| <1 hour training |
| Training Available |
| No |
| Manuals Available |
| Yes |
| Warranties |
| No |
| IATA Shipping Restrictions |
| None |
| Approved Vendors |
| Fisher, Grainger |