TruNarc™

Thermo Scientific™ TruNarc™ Handheld Narcotics Analyzer enables officers, customs, border control, and other personnel to scan more than 415 suspected illicit substances in a single, definitive test using Raman technology.

Notify me on updates of this product 

Availability: Commercially Available

Dan Davis
Product Manager
daniel.davis2@thermofisher.com
978-513-9717
2 Radcliff Road
Tewksbury, MA 01876
USA
www.thermoscientific.com
Manufacturer
Thermo Fisher Scientific, Inc.
Product Name
TruNarc™
Detection Category
Chemical
Detection Principle
Molecular Spectroscopy;
Detection Method
Raman Spectroscopy;
Application
Emergency Response;Forensics;Screening;
Equipment Type
Instrument
Product Synopsis
Thermo Scientific™ TruNarc™ Handheld Narcotics Analyzer enables officers, customs, border control, and other personnel to scan more than 415 suspected illicit substances in a single, definitive test using Raman technology.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
MRIGlobal hands-on experience
Supporting Documentation
Docs: Thermo - TruNarc.pdf;
Dimensions
6.4 x 4.1 x 2.0 in (16.26 x 10.41 x 5.10 cm)
Weight
<5 Lbs.; 1.25 Lbs. (0.57 kg)
Power Requirements
AC/DC Line Power; Lithium Battery; Rechargeable internal 3.7V battery pack (10 hours); DC wall adapter, 5V DC, 1.5A; optional car charger
Transportability
Handheld
Ruggedness
Waterproof/Resistant; Dust; IP64
Operating Conditions
-10 to 50°C (14 to 122°F)
Consumables
<$1,000/year; sample vials
Available Accessories
Car charger
Data Analysis Support Equipment
PC, software
Communications Interface
micro USB
Expected Operational Life
Indefinite
Shelf Life
>5 years
Tested For Narcotics
Opioids, fentanyls, carfentanil, alfentanil, sufentanil, ketamine, U-47700, lorazepam, remifentanil, heroin, 3-quinuclidinyl benzilate, common street fentanyl analogues, ANPP, NPP, methamphetamine, others
Other Chemical Targets
Aspirin, ephedrine, sugar, lactose, caffeine, ibuprofen, others
Number of Library Entries
415+ entries, Controlled substances, cutting agents, and precursors including: heroin, synthetic drugs on leaf materials or blotter paper
Sample Introduction
Liquid; Solid;
Sensitivity/Detection Limits
~10%
Start Up Time (From Cold Start To Sample Ready)
Minutes
Response Time (Sample Application To Output)
<1 minute; < 40 seconds
Total Run Time
Minutes
Alarm Capability
Yes
Software Control
On-board, PC
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Reachback Service
Yes
Warranties
Yes
IATA Shipping Restrictions
No
Data File Type Format
CSV, XLS, SPC, PDF
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: