TruScan RM
The TruScan RM analyzer includes optics paired with a patented multivariate residual analysis that offers an effective chemometric solution for material identification, with two spectral pre-processing options. The analyzer’s non-destructive point-and-shoot sampling principle facilitates rapid verification of a broad range of chemical compounds, including cellulose-based products.
Availability: Commercially Available
| Manufacturer |
| Thermo Fisher Scientific, Inc. |
| Product Name |
| TruScan RM |
| Detection Category |
| Chemical; Explosives |
| Detection Principle |
| Molecular Spectroscopy; |
| Detection Method |
| Raman Spectroscopy; |
| Application |
| Bulk Analysis;Screening;Emergency Response; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The TruScan RM analyzer includes optics paired with a patented multivariate residual analysis that offers an effective chemometric solution for material identification, with two spectral pre-processing options. The analyzer’s non-destructive point-and-shoot sampling principle facilitates rapid verification of a broad range of chemical compounds, including cellulose-based products. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| MRIGlobal hands-on experience |
| Supporting Documentation |
| Docs: Thermo - TruScan Rm.pdf; |
| Dimensions |
| 8.2 x 4.2 x 1.7 in (20.8 x 10.7 x 4.3 cm) |
| Weight |
| <5 Lbs.; < 2 Lbs. (0.9 kg) |
| Power Requirements |
| Lithium Battery; AC/DC Line Power; Li-ion battery, DC (> 4 hours); DC Wall Adapter, 100-240VAC 50/60Hz |
| Transportability |
| Handheld |
| Ruggedness |
| Extreme Temperatures/Humidity; drop resistant |
| Operating Conditions |
| -20 to 40°C (-4 to 104°F) |
| Consumables |
| <$1,000/year; sample vials |
| Available Accessories |
| Vial holder, universal tablet holder, cuvette holder |
| Data Analysis Support Equipment |
| Microsoft Windows 7,8,10, Internet Explorer 11, Edge 25;
Google Chrome 51 |
| Communications Interface |
| Ethernet |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Tested For Chemical Agents |
| Amenable based on technology |
| Tested For ITF-25 TIC/TIMs |
| Amenable based on technology |
| Tested For Explosives |
| Amenable based on technology |
| Tested For Narcotics |
| Amenable based on technology |
| Adaptability |
| Yes; user can add new targets in the field |
| Sample Introduction |
| Liquid; Solid; |
| Sensitivity/Detection Limits |
| %; Bulk; g; mg |
| Known Interferents/Inhibitors |
| Fluorescence |
| Start Up Time (From Cold Start To Sample Ready) |
| < 5 minutes |
| Response Time (Sample Application To Output) |
| <1 minute; < 40 seconds |
| Total Run Time |
| < 5 minutes |
| Software Control |
| On-board, PC |
| Other Operational Parameters |
| Spectrum range: 250 to 2875 cm-1, 785nm |
| Training Required |
| <1 day training |
| Training Available |
| Yes |
| Manuals Available |
| Yes |
| Reachback Service |
| Yes |
| Warranties |
| Yes |
| IATA Shipping Restrictions |
| Yes; Lithium ion battery |