SC420 CBRN Powered Air Purifying Respirator (PAPR)
The SC420 CBRN PAPR includes the Survivair Opti-Fit™ CBRN Facepiece, Blower Unit, Breathing Hose, Power Supply and Canisters.
Availability: Commercially Available
| Manufacturer |
| Honeywell International, Inc. |
| Product Name |
| SC420 CBRN Powered Air Purifying Respirator (PAPR) |
| Detection Category |
| Chemical; Biological; Radiological/Nuclear |
| Detection Method |
| PPE/Decon; |
| Application |
| Personal Protective Equipment; |
| Equipment Type |
| PPE |
| Product Synopsis |
| The SC420 CBRN PAPR includes the Survivair Opti-Fit™ CBRN Facepiece, Blower Unit, Breathing Hose, Power Supply and Canisters. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Supporting Documentation |
| Docs: SC420 CBRN_PAPR_Broch_Final.pdf; |
| Dimensions |
| 10 x 12 x 3.5 in (25 x 31 x 8.9 cm) |
| Weight |
| <30 lbs.; 7 lbs. (3.2 kg) |
| Power Requirements |
| NiMH Battery; Rechargeable |
| Transportability |
| Person-Portable |
| Operating Conditions |
| -32 to 49°C (-26 to 120°F) |
| Available Accessories |
| D-ring option for decon belt with a pull force of over 1,000 lbs, Black Carrying Case |
| Shelf Life |
| >5 years; when stored in original packaging |
| Unit Cost |
| $1,700.00 |
| Batteries |
| Three power supply options: – D Cell Holder Pack — Holds four off-the-shelf D cell alkaline batteries, NiMH, LiSO2 |
| Decontaminable |
| Yes |
| Drinking Capability |
| Yes |
| Flow Rate |
| 115 to 140 LPM |
| Live Agent Tested |
| Yes |
| Material |
| Butyl rubber |
| Number of Filters |
| 2 |
| Number of Speeds |
| 1 |
| Operating Time |
| 2 hours |
| Standards Met |
| MIL-STD-461C,Part 4, RE02 |
| Working Life |
| > 1,000 hours (Blower) |
| Other Operational Parameters |
| See Survivair Opti-Fit™ CBRN Respirator for technical specs |
| Training Required |
| <1 hour training |
| Training Available |
| Yes - Video |
| Manuals Available |
| Yes |
| Warranties |
| Yes |