Griffin™ G510

The FLIR Griffin™ G510 GC/MS is a versatile, person-portable chemical identifier. It can analyze all phases of matter (liquid, solid, vapor). The integrated heated sample probe enables hot zone operators to identify vapor-phase chemical threats within seconds when operated in Survey Mode. The integrated split/splitless injector allows for environmental, forensic, and hazardous material sampling via syringe injection of organic liquids. The 9” touchscreen can be operated while wearing full PPE downrange. It is built with an IP65-rated enclosure.

Notify me on updates of this product 

Availability: Commercially Available

Toby Kennedy
DoD Sales and BD Manager
toby.kennedy@teledyneflir.com
580-761-7191
27720 SW Parkway Avenue
Wilsonville, OR 97090
The Americas, EMEA, APAC
Contact for pricing, availability and 3rd party vendors
https://www.flir.com/browse/government-defense/cbrne-detectors/
Manufacturer
Teledyne FLIR Detection, Inc.
Product Name
Griffin™ G510
Detection Category
Chemical; Explosives;
Detection Principle
Spectrometry; Chromatography;
Detection Method
Quadrupole Mass Spectrometry;Gas Chromatography;
Application
Trace Analysis; Emergency Response; Forensics; Laboratory Analysis;
Equipment Type
Instrument
Product Synopsis
The FLIR Griffin™ G510 GC/MS is a versatile, person-portable chemical identifier. It can analyze all phases of matter (liquid, solid, vapor). The integrated heated sample probe enables hot zone operators to identify vapor-phase chemical threats within seconds when operated in Survey Mode. The integrated split/splitless injector allows for environmental, forensic, and hazardous material sampling via syringe injection of organic liquids. The 9” touchscreen can be operated while wearing full PPE downrange. It is built with an IP65-rated enclosure.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Market Entry Date
June 5, 2017
User Feedback Sources
Positive user feedback; MRIGlobal Hands-on experience
Supporting Documentation
Docs: Field (2).pdf;
Dimensions
13.25 x 13.25 x 15.75 in (33.7 x 33.7 x 40 cm) - includes batteries, carrier gas, and vacuum system
Weight
<50 Lbs.; 36 Lbs. (16.3 kg) - includes batteries, carrier gas, and vacuum system
Power Requirements
Lithium Battery; AC/DC Line Power; 100-240V 50-60Hz (220 W max); 19V (DC); 2 x #2590 @ 15V Li Ion batteries (1 included) 4 hours in Survey Mode, 2 hours in Confirmation Mode; hot swappable
Noise Produced
Negligible
Transportability
Person-Portable
Ruggedness
Dust; Waterproof/Resistant; Sealed for Survey Mode operation in hot-zone; IP65-rated enclosure is dust-tight and spray-resistant; Scheduled for shock/vibration, temperature, and humidity testing.
Operating Conditions
0 to 40 °C (32 to 104 °F), 95% RH
Consumables
<$1,000/year; On-board helium; external helium connector, automatic switching (Hydrogen capable)
Solvents/Reagents
Carrier gas, On-board FC-43 (Perfluorotributylamine) calibrant
Calibration Schedule
Daily; autotune
Suggested Routine Maintenance
GC inlet (as needed), Filament replacement (twice per year), Refill calibrant (annually)
Available Accessories
Liquid extraction via SPME fiber or PSI-Probe w/ Gerstel Twister™, Solid PSI-Probe™ thermal separation via TAG™
Data Analysis Support Equipment
9 inch on-board touchscreen
Communications Interface
2 x USB 2.0, Bluetooth 4.0, Wi-Fi 802.11n, Ethernet via USB, integrated GPS
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$125,000.00
Maintenance Cost
< $1,000 annually
Tested For Chemical Agents
Yes
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Yes
Tested For Narcotics
Yes
Other Chemical Targets
Yes
Number of Library Entries
GriffinLib (500 spectra), NIST EPA (10,000 spectra), NIST (240,000 spectra)
Adaptability
Yes; user can add new targets in the field and create custom searchable libraries
Sample Introduction
Liquid;Solid;Vapor/Gas;
Sensitivity/Detection Limits
ppm; ppb; ng
Known Interferents/Inhibitors
None
False Positive Rates
<1% False Positive and Negative Rate
False Negative Rates
0
Start Up Time (From Cold Start To Sample Ready)
15 minutes
Response Time (Sample Application To Output)
<15 minutes; 4 to 15 minutes
Total Run Time
19 to 30 minutes
Alarm Capability
Audible and Visual
Software Control
On-board; multiple user levels
Other Operational Parameters
Programmable 40 to 300 °C; ramping of 100 °C/min; Mass Range and Resolution: 15-515 m/z; 0.7 amu @ FWHM
Training Required
<1 week training
Training Available
2 hours basic operation; 8 hours expert user
Manuals Available
Yes
Reachback Service
Yes
Warranties
Yes
ITAR/EAR Export Regulations
Yes
IATA Shipping Restrictions
None; Requires Lithium Battery Signage
Data File Type Format
Proprietary software data file format, exportable to 3rd party software
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: