G908

G908 is a multi-column, plug-and-go device. This 28-pound analyzer combines the separation speed of ballistic gas chromatography, the compound selectivity of high pressure mass spectrometry (HPMS), and the analytical capabilities of FID and TCD, to provide qualitative and quantitative results. The alliance of capillary column separations, conventional GC detection and novel microscale ion trap technology, ensures reduced analysis times – from minutes to seconds – for a wide range of compounds.

Notify me on updates of this product 

Availability: Commercially Available

John Kenneweg
Vice President of Sales, Safety & Security
john.kenneweg@908devices.com
+1 857 254 1500
27 Drydock Avenue
Boston, MA 02210
USA
Jim Kane
Director of Federal Programs
jim.kane@908devices.com
+1 757 746 5554
www.908devices.com
Manufacturer
908 Devices, Inc.
Product Name
G908
Detection Category
Chemical; Explosives;
Detection Principle
Spectrometry;Chromatography;
Detection Method
Ion Trap Mass Spectrometry;Gas Chromatography;
Application
Emergency Response;Forensics;Gas Analysis;Screening;
Product Model Number
G908
Equipment Type
Instrument
Product Synopsis
G908 is a multi-column, plug-and-go device. This 28-pound analyzer combines the separation speed of ballistic gas chromatography, the compound selectivity of high pressure mass spectrometry (HPMS), and the analytical capabilities of FID and TCD, to provide qualitative and quantitative results. The alliance of capillary column separations, conventional GC detection and novel microscale ion trap technology, ensures reduced analysis times – from minutes to seconds – for a wide range of compounds.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Market Entry Date
Fall 2016
Dimensions
17 x 11 x 12 in (43 x 28 x 30 cm)
Weight
28 lbs (12.7 kg)
Power Requirements
24VDC from external power supply 100 to 240 VAC 50/60Hz
Noise Produced
Negligible
Transportability
Person-Portable
Durability
Rugged, Field Deployable, no shock or vibration testing
Operating Conditions
0 to 40°C (32 to 104°F)
Consumables
TD swabs
Solvents/Reagents
Carrier gas: helium, hydrogen or nitrogen
Data Analysis Support Equipment
Software
Communications Interface
USB
Expected Operational Life
Indefinite
Shelf Life
Indefinite
Unit Cost
$50,000 to $65,000 depending on configuration
Tested For Chemical Agents
Yes
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Yes
Tested For Narcotics
No
Other Chemical Targets
Yes
Customize For New Targets
No
Sample Introduction
Liquid;Vapor/Gas;
Sensitivity/Detection Limits
ppb to ppm
Response Time (Sample Application To Output)
< 5 minutes
Total Run Time
Minutes
Software Control
On-board, PC
Other Operational Parameters
Non-radioactive, internal glow discharge ionization (70eV), positive mode. Unit Mass Accuracy 1 m/z (40-250 m/z range with 100ppm BTEX calibration standard). Unit mass range 15 to 450; Gas/Liquid injection.
Operator Skills Required
Minimal technical background
Training Available
Yes, 4 hours on-site
Manuals Available
Yes
Reachback Service
Yes
Warranties
Yes
ITAR Export Regulations
None
IATA Shipping Restrictions
Li-ion battery
Approved Vendors
Federal Resources
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: