Sentry EC

The Radiation Alert® Sentry EC is a Personal Alarming Dosimeter / Ratemeter designed to ensure the safety of personnel that work in occupations with potential x-ray or gamma exposure. The pocket sized unit has an energy compensated tube for a linear response to gamma and built in memory for recording data points for tracking accumulated exposure. The SentryCom Software option enables you to generate incident reconstruction for analysis.

Notify me on updates of this product 

Availability: Commercially Available

radiationinfo@seintl.com
+1 931 964 3561
P.O. Box 39, 436 Farm Road
Summertown, TN 38483
USA
www.seintl.com
Manufacturer
S.E. International, Inc.
Product Name
Sentry EC
Detection Category
Radiological/Nuclear
Detection Principle
Geiger-Muller Detectors;
Detection Method
Geiger-Muller Detectors;
Application
Dosimeters;
Equipment Type
Instrument
Product Synopsis
The Radiation Alert® Sentry EC is a Personal Alarming Dosimeter / Ratemeter designed to ensure the safety of personnel that work in occupations with potential x-ray or gamma exposure. The pocket sized unit has an energy compensated tube for a linear response to gamma and built in memory for recording data points for tracking accumulated exposure. The SentryCom Software option enables you to generate incident reconstruction for analysis.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
4.2 X 2.7 X 1.1 in (106 x 67 x 28 mm)
Weight
<1 lb.; 8.6 oz (243 g)
Power Requirements
Alkaline Battery; 9-Volt Alkaline Battery (1,500 hours)
Transportability
Pocket Size
Ruggedness
Extreme Temperatures/Humidity; Anodized Aluminum Housing with Metal Belt Clip
Operating Conditions
-20 to 50°C (-4 to 122°F)
Consumables
None
Available Accessories
SentryCom software
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$400.00
Radiological Targets
Gamma, X-ray
Adaptability
No; cannot detect or add new targets
Sample Introduction
Radioactive Particle
Sensitivity/Detection Limits
mR
Start Up Time (From Cold Start To Sample Ready)
Seconds
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous monitor
Alarm Capability
Audible, visual, and vibrational
Software Control
On-board
Training Required
<1 day training
Training Available
Yes
Manuals Available
Operations Manual
Warranties
1 year
ITAR/EAR Export Regulations
No
IATA Shipping Restrictions
No
Approved Vendors
Grainger
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: