KeDetect CW NAIAD
The KeDetect CW NAIAD (Nerve Agent Immobilized-enzyme Alarm Detector) is a battery powered CWA biosensor. The vendor claims the NAIAD can detect all known and unknown nerve agents, including Novichok and FTA variants. Limits of detection are sub-miosis level. Also detects attack concentrations of hydrogen cyanide (HCN). The vendor literature does not provide details of the sensing technology used in this product.
Availability: DISCONTINUED
Robert Chandler
Business Development Manager
44 1159 005600
Glaisdale Drive East
Nottingham, UK
Nottinghamshire
9am - 5pm, Mon - Fri
|
Maggie McBrearty
Sales Admin
44 1159 005600
Glaisdale Drive East
Nottingham, UK
Nottinghamshire
9am - 5pm, Mon - Fri
|
www.ketechdefence.com
| Manufacturer |
| KeTech Systems Ltd |
| Product Name |
| KeDetect CW NAIAD |
| Detection Category |
| Chemical; |
| Detection Principle |
| Sensors; |
| Detection Method |
| Enzymatic; |
| Application |
| Emergency Response; Screening; Bulk Analysis; Trace Analysis; |
| Product Model Number |
| NAIAD |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The KeDetect CW NAIAD (Nerve Agent Immobilized-enzyme Alarm Detector) is a battery powered CWA biosensor. The vendor claims the NAIAD can detect all known and unknown nerve agents, including Novichok and FTA variants. Limits of detection are sub-miosis level. Also detects attack concentrations of hydrogen cyanide (HCN). The vendor literature does not provide details of the sensing technology used in this product. |
| Availability |
| DISCONTINUED |
| Technology Readiness Level (TRL) |
| 9 |
| Market Entry Date |
| 1985 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 39 x 25 x 21cm |
| Weight |
| <30 lbs.; 10Kg |
| Power Requirements |
| NiMH Battery; Lithium Battery; Battery 24V |
| Noise Produced |
| 95Db |
| Transportability |
| Person-Portable |
| Ruggedness |
| Waterproof/Resistant; Dust; Vibration/Shock; MIL-STD, IP rated |
| Operating Conditions |
| 0 to 50°C (32 to 122°F) |
| Consumables |
| >$1,000/year; Chemical Reagent Module, Enzyme Pad |
| Solvents/Reagents |
| Liquid; Solid |
| Calibration Schedule |
| None |
| Suggested Routine Maintenance |
| Keep inlet free of obstructions |
| Available Accessories |
| Remote Alarm, Ruck Sack, Field Test Kit |
| Expected Operational Life |
| 10 years |
| Shelf Life |
| >5 years |
| Maintenance Cost |
| Consumable change every 12 hours of active operation |
| Tested For Chemical Agents |
| All Known and Not specified Nerve Agents |
| Tested For ITF-25 TIC/TIMs |
| Yes |
| Tested For Explosives |
| No |
| Tested For Narcotics |
| No |
| Other Chemical Targets |
| Hydrogen Peroxide |
| Tested For Biological Agents |
| No |
| Other Biological Targets |
| No |
| Radiological Targets |
| No |
| Sample Introduction |
| Vapor/Gas |
| Sensitivity/Detection Limits |
| ppb |
| False Positive Rates |
| 0 |
| Start Up Time (From Cold Start To Sample Ready) |
| 5 minutes |
| Response Time (Sample Application To Output) |
| Continuous (<30 seconds); < 1 second |
| Alarm Capability |
| Audio; Visual |
| Software Control |
| No |
| Training Required |
| <1 week training |
| Training Available |
| Yes |
| Manuals Available |
| Yes |
| Warranties |
| Yes |