Solaris Multigas Detector
The Solaris Multigas Detector is a personal monitor for detection of oxygen, hydrogen sulfide, carbon monoxide and combustible gases. The four in one gas detector displays all gas readings simultaneously.
Availability: DISCONTINUED
Manufacturer |
| Mine Safety Appliances Company (MSA) |
Product Name |
| Solaris Multigas Detector |
Detection Category |
| Chemical |
Detection Principle |
| Sensors; |
Detection Method |
| Catalytic Bead Sensor; Electrochemical Detection; |
Application |
| Emergency Response; Gas Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| The Solaris Multigas Detector is a personal monitor for detection of oxygen, hydrogen sulfide, carbon monoxide and combustible gases. The four in one gas detector displays all gas readings simultaneously. |
Availability |
| DISCONTINUED |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Weight |
| <1 lb.; < 8 oz (0.23 kg) |
Power Requirements |
| Lithium Battery; Alkaline Battery |
Transportability |
| Pocket Size |
Operating Conditions |
| 0 to 40°C (32 to 104°F) |
Consumables |
| <$1,000/year; Batteries; Sensors; Filters |
Calibration Schedule |
| Daily; more frequently if subjected to physical shock or exposed to silicone, silicates, lead-containing compounds, hydrogen sulfide, or high contaminant levels. |
Suggested Routine Maintenance |
| Cleaning and periodic checks |
Available Accessories |
| Powered sampling pump; Sampling probe; Power Supply; Rear Case Assembly; Main PC Board Assembly |
Communications Interface |
| Galaxy system compatible |
Expected Operational Life |
| 10 years |
Shelf Life |
| >5 years |
Unit Cost |
| $1,417.00 |
Maintenance Cost |
| Minimal |
Tested For Chemical Agents |
| No |
Tested For ITF-25 TIC/TIMs |
| Combustible gases |
Tested For Explosives |
| No |
Tested For Narcotics |
| No |
Other Chemical Targets |
| Carbon monoxide, hydrogen sulfide, oxygen |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppm; LEL |
Known Interferents/Inhibitors |
| Some gases may reduce the sensitivity of the combustible gas sensor by polymerizing on the catalytic surface. |
Start Up Time (From Cold Start To Sample Ready) |
| 2 minutes |
Response Time (Sample Application To Output) |
| <1 minute |
Total Run Time |
| < 5 minutes |
Alarm Capability |
| Audible, visual and vibration |
Other Operational Parameters |
| None |
Training Required |
| <1 hour training |
Training Available |
| Yes |
Manuals Available |
| User's Manual |
Reachback Service |
| No |
Warranties |
| 2 years |