RDS-31 Survey Meter

The RDS-31S/R Multi-purpose Survey Meter is a small hand held, battery operated survey instrument using an energy compensated GM-tube as primary detector. External probes of GMP-12 series, GMP-11/15 and Multirad LLR probes: TGS, Alpha 125 and Alpha Wound can be connected to RDS-31 by cable or by additional adapter extending the capabilities of the instrument.

Notify me on updates of this product 

Availability: Commercially available

Carol McGowan
Homeland Security and Defense Sales Manager
cmcgowan@mirion.com
+1 770 329 3228
5000 Highlands Parkway, Suite 150
Smyrna, GA 30082
USA
+1 770 432 2744
www.mirion.com
Manufacturer
Mirion Technologies
Product Name
RDS-31 Survey Meter
Detection Category
Radiological/Nuclear
Detection Principle
Geiger-Muller Detectors;
Detection Method
Geiger-Muller Detectors;
Application
Identifiers; Survey Meter;
Equipment Type
Instrument
Product Synopsis
The RDS-31S/R Multi-purpose Survey Meter is a small hand held, battery operated survey instrument using an energy compensated GM-tube as primary detector. External probes of GMP-12 series, GMP-11/15 and Multirad LLR probes: TGS, Alpha 125 and Alpha Wound can be connected to RDS-31 by cable or by additional adapter extending the capabilities of the instrument.
Availability
Commercially available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
3.93 x 2.63 x 1.29 in (10 x 6.7 x 3.3 cm)
Weight
<1 lb.; 0.385 lb (0.17 kg)
Power Requirements
Alkaline Battery; 2 AA battery (4 months at 8 hours per day usage)
Transportability
Pocket Size
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP67, high impact case
Operating Conditions
-25 to 60°C (-40 to 131°F)
Consumables
None
Available Accessories
Electrical cradle or mechanical cradle e.g. for easy vehicle fixing, table top model, pocket/belt clip/pouch
Communications Interface
RF-communication, USB
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$1,669.00
Radiological Targets
Alpha, Beta, Gamma, X-ray
Sample Introduction
Radioactive Particle
Sensitivity/Detection Limits
µSv; 0.01 µSv
Start Up Time (From Cold Start To Sample Ready)
Seconds
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous monitor
Alarm Capability
Audible, vibrational, and visual
Software Control
On-board
Other Operational Parameters
Two button operation
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Reachback Service
No