AMP Radiation Monitoring System Series
Offered in a wide range of measurement ranges, the AMP series of area radiation monitors provide real-time remote radiological measurement. Featuring waterproof probes and available cables anywhere from 25 to 350 feet in length, they can safely measure in areas where high radiation could otherwise compromise meter electronics. Model types are based on their linear response. AMP 50: 10 uR/hr to 4 R/hr. AMP 100: 0.5 to 1000 mR/hr. AMP 200: 5 to 10,000 R/hr.
Availability: Commercially available
Carol McGowan
Homeland Security and Defense Sales Manager
cmcgowan@mirion.com
+1 770 329 3228
5000 Highlands Parkway, Suite 150
Smyrna, GA 30082
USA
|
+1 770 432 2744
|
www.mirion.com
Manufacturer |
| Mirion Technologies |
Product Name |
| AMP Radiation Monitoring System Series |
Detection Category |
| Radiological/Nuclear |
Detection Principle |
| Geiger-Muller Detectors; |
Detection Method |
| Geiger-Muller Detectors; |
Application |
| Identifiers; Survey Meter; |
Product Model Number |
| AMP 50, AMP 100, AMP 200 |
Equipment Type |
| Instrument |
Product Synopsis |
| Offered in a wide range of measurement ranges, the AMP series of area radiation monitors provide real-time remote radiological measurement. Featuring waterproof probes and available cables anywhere from 25 to 350 feet in length, they can safely measure in areas where high radiation could otherwise compromise meter electronics. Model types are based on their linear response. AMP 50: 10 uR/hr to 4 R/hr. AMP 100: 0.5 to 1000 mR/hr. AMP 200: 5 to 10,000 R/hr. |
Availability |
| Commercially available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 2.7 x 4.7 x 0.5 in (6.9 x 12 x 1 cm) |
Weight |
| <1 lb.; 7.9 oz (0.22 kg) |
Power Requirements |
| Alkaline Battery; 9v battery |
Transportability |
| Handheld |
Ruggedness |
| Waterproof/Resistant; waterproof detector housing and cable |
Operating Conditions |
| -10 to 50°C (15 to 120° F ) |
Consumables |
| None |
Communications Interface |
| Built in communication port for use with WRM2 EXT transmitter |
Shelf Life |
| >5 years |
Radiological Targets |
| Gamma |
Sample Introduction |
| Radioactive Particle |
Sensitivity/Detection Limits |
| cps; 330 CPS |
Start Up Time (From Cold Start To Sample Ready) |
| < 2 minutes |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Total Run Time |
| Continuous |
Alarm Capability |
| Yes |
Training Required |
| <1 week training |
Training Available |
| Yes |
Manuals Available |
| Yes |
Reachback Service |
| No |