EnVision Gossamer
EnVision GOSSAMER is a ruggedized, field deployable CBRN surveillance system formed by CBRN measuring and data processing units, command and control posts with GIS based CBRN monitoring software, PDAs for local user interface and related radio communication systems and power supplies. Temporary, mobile sensor fields for CBRN detection can be created using Chempro DM inside.
Availability: DISCONTINUED
Manufacturer |
| Environics Oy |
Product Name |
| EnVision Gossamer |
Detection Category |
| Chemical; Radiological/Nuclear |
Detection Principle |
| Spectrometry |
Detection Method |
| Ion Mobility Spectrometry; Surface active microsensors; |
Application |
| Emergency Response; Screening; Identifiers; Detection; |
Equipment Type |
| Instrument |
Product Synopsis |
| EnVision GOSSAMER is a ruggedized, field deployable CBRN surveillance system formed by CBRN measuring and data processing units, command and control posts with GIS based CBRN monitoring software, PDAs for local user interface and related radio communication systems and power supplies. Temporary, mobile sensor fields for CBRN detection can be created using Chempro DM inside. |
Availability |
| DISCONTINUED |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 20.6 x 16.9 x 8.1 in (52.4 x 42.8 x 20.6 cm) |
Weight |
| <30 Lbs.; 22 Lbs. (10 kg) |
Power Requirements |
| AC/DC Line Power; 100 to 240 VAC (72 hours) |
Transportability |
| Person-Portable |
Ruggedness |
| Extreme Temperatures/Humidity |
Operating Conditions |
| -30 to 50°C (-22 to 122 °F) |
Consumables |
| None |
Calibration Schedule |
| Confidence check only |
Suggested Routine Maintenance |
| Filters and pumps |
Available Accessories |
| Radiation detection module (ChemPro RDM); Remote Alarm Unit (ChemPro RAU); Standard Accessories Kit: ChemProPD, Communication Module, Tripod, Fastener and attachment tools, Test tube & Inner filter set, Main Power Supply (Charger) |
Data Analysis Support Equipment |
| Touch Screen PC |
Communications Interface |
| Ethernet (RJ45); RS232 for the Radio Communication Module; USB; |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Unit Cost |
| $81.287.00 (Sold in Euros so cost may change depending on exchange rate at point of sale) |
Maintenance Cost |
| Negligible |
Tested For Chemical Agents |
| Yes |
Radiological Targets |
| Gamma and X-ray |
Number of Library Entries |
| 20 libraries with 50 compounds each |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppm |
Start Up Time (From Cold Start To Sample Ready) |
| 60 to 90 seconds |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Total Run Time |
| Continuous |
Alarm Capability |
| Audible and Visible |
Software Control |
| PC |
Training Required |
| <1 week training |
Training Available |
| Yes |
Manuals Available |
| User's manual |
Warranties |
| 1 year |
IATA Shipping Restrictions |
| Not Specified |