600 Series UV Fluorescent SO2
The California Analytical Series 600 digital analyzer product line is designed around a 16 bit microprocessor, with 16 digital inputs, 16 digital outputs, 16 analog inputs and 4 analog outputs. The analyzer can be manually operated from the keypad or remotely via TCP/IP, RS-232 communications and discrete inputs. The analyzer display includes screen presentation of all analyzer alarms. Four levels of password protection are provided. For precision measurements, the analyzers’ accuracy is increased by entering calibration curve fit polynomials. Automatic calibration may be activated locally or remotely and includes auto calibration via preset times.
Availability: DISCONTINUED
Manufacturer |
| ENVEA |
Product Name |
| 600 Series UV Fluorescent SO2 |
Detection Category |
| Chemical; Explosives |
Detection Principle |
| Molecular Spectroscopy; |
Detection Method |
| Ultraviolet-Visible; Fluorescence; |
Application |
| Gas Analysis; |
Equipment Type |
| Instrument |
Product Synopsis |
| The California Analytical Series 600 digital analyzer product line is designed around a 16 bit microprocessor, with 16 digital inputs, 16 digital outputs, 16 analog inputs and 4 analog outputs. The analyzer can be manually operated from the keypad or remotely via TCP/IP, RS-232 communications and discrete inputs. The analyzer display includes screen presentation of all analyzer alarms. Four levels of password protection are provided. For precision measurements, the analyzers’ accuracy is increased by entering calibration curve fit polynomials. Automatic calibration may be activated locally or remotely and includes auto calibration via preset times. |
Availability |
| DISCONTINUED |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Dimensions |
| 5¼ x 19 x 23 in (13 x 48 x 58 cm) |
Weight |
| <50 lbs.; 30 to 45 lbs (14 to 20 kg) |
Power Requirements |
| AC/DC Line Power; 115/230 (+/- 10%) VAC; 50/60Hz, 300 watts maximum |
Transportability |
| Benchtop/Fixed; Small Footprint |
Operating Conditions |
| 5 to 40°C (41 to 105°F); < 90% RH (non-condensing) |
Consumables |
| None |
Calibration Schedule |
| Automatic calibration may be activated locally or remotely |
Available Accessories |
| Internal Sample Pump; NDIR CO2 Channel; Paramagnetic O2 Channel |
Data Analysis Support Equipment |
| Remote PC or laptop |
Communications Interface |
| TCP/IP, RS-232, Four Scalable Analog 0-10V / 4-20mA (Allows Offset & Expandable Range DC Analog Outputs) |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Maintenance Cost |
| Minimal |
Tested For Chemical Agents |
| Yes |
Tested For Explosives |
| Yes |
Other Chemical Targets |
| SO2 |
Sample Introduction |
| Vapor/Gas |
Sensitivity/Detection Limits |
| ppm |
Start Up Time (From Cold Start To Sample Ready) |
| < 5 minutes |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds); 17 seconds |
Total Run Time |
| < 5 minutes |
Alarm Capability |
| Audible and visual |
Software Control |
| On-board, PC |
Training Required |
| <1 week training |
Training Available |
| Yes |
Manuals Available |
| Operator's manual |
Warranties |
| 1 to 4 years |
IATA Shipping Restrictions |
| No |