600 FTIR

The California Analytical Instruments 600 FTIR Analyzer provides continuous and stable analysis of virtually any gas that has an infrared absorption spectrum. The proprietary heated sample cell enables the instrument to accommodate hot samples containing high levels of moisture. The SC model includes a short cell for higher concentration levels.

Notify me on updates of this product 

Availability: Commercially Available

Darrell Parson
dparson@gasanalyzers.com
+1 800 959 0949 ext. 306
1312 West Grove Avenue
Orange, CA 92865-4134
www.gasanalyzers.com
Manufacturer
ENVEA
Product Name
600 FTIR
Detection Category
Chemical; Explosives
Detection Principle
Molecular Spectroscopy;
Detection Method
Mid-infrared Spectroscopy;
Application
Gas Analysis;
Product Model Number
600, 600SC
Equipment Type
Instrument
Product Synopsis
The California Analytical Instruments 600 FTIR Analyzer provides continuous and stable analysis of virtually any gas that has an infrared absorption spectrum. The proprietary heated sample cell enables the instrument to accommodate hot samples containing high levels of moisture. The SC model includes a short cell for higher concentration levels.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
7.0 x 19 x 24 in (18 x 48 x 61 cm)
Weight
>50 lbs.; 65 to 70 lbs (29 to 32 kg)
Power Requirements
AC/DC Line Power; 115 VAC/60Hz or 230 VAC/50Hz
Transportability
Benchtop/Fixed; Small Footprint
Operating Conditions
5 to 40°C (41 to 105°F); < 80% RH (non-condensing)
Consumables
None
Available Accessories
Pressure compensation; Analog output module; Intelligent multi-point sampler; Sample accessories
Data Analysis Support Equipment
Rack-mount PC or laptop-controlled , OPUS software for Windows XP or higher.
Communications Interface
RS-232
Expected Operational Life
Indefinite
Shelf Life
>5 years
Maintenance Cost
Minimal
Tested For Chemical Agents
Yes
Tested For Explosives
Yes
Other Chemical Targets
IR active gases
Adaptability
Yes; manufacturer can add new targets to detector
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppb
Start Up Time (From Cold Start To Sample Ready)
20 seconds to 5 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds); Seconds
Total Run Time
Continuous
Software Control
PC
Other Operational Parameters
It does not require liquid nitrogen.
Training Required
<1 week training
Training Available
Yes
Manuals Available
Operator's manual
Warranties
1 to 4 years
IATA Shipping Restrictions
No