RAID-XP

The RAID-XP is a highly flexible instrument, both in terms of detection capabilities (N+C) and lightweight and portable design. It is based on the principle of ion mobility spectrometry.

Notify me on updates of this product 

Availability: Commercially available

Frank Thibodeau
Vice President of Business Development
frank.thibodeau@brukerdetection.us
+1 978 663 3660
40 Manning Road
Billerica, MA 01821
USA
www.bruker.com
Manufacturer
Bruker Corporation
Product Name
RAID-XP
Detection Category
Chemical; Explosives; Radiological/Nuclear
Detection Principle
Spectrometry;
Detection Method
Ion Mobility Spectrometry;
Application
Emergency Response; Screening; Gas Analysis; Identifiers;
Equipment Type
Instrument
Product Synopsis
The RAID-XP is a highly flexible instrument, both in terms of detection capabilities (N+C) and lightweight and portable design. It is based on the principle of ion mobility spectrometry.
Availability
Commercially available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
6.2 x 8.7 x 11 in (160 x 220 x 280 mm)
Weight
<30 Lbs.; 15 Lbs. (7 kg), without battery
Power Requirements
AC/DC Line Power; External power supply, accumulator/battery Low voltage DC power (9 to 32 V DC nominal) Mains power supply: 230 V 50 Hz (110 V 60 Hz) AC
Noise Produced
Negligible
Transportability
Handheld
Ruggedness
Extreme Temperatures/Humidity
Operating Conditions
–30 to 50°C (-22 to 122°F)
Consumables
<$1,000/year; Dust, purge, and drying filters, dopant. Filters are rated for 500 operating hours
Calibration Schedule
No
Suggested Routine Maintenance
Filter and dopant replacement every 500 hours
Data Analysis Support Equipment
XIMS-NT software
Communications Interface
GPS enabled; RS232 interface to remote computer
Expected Operational Life
1 to 2 years
Shelf Life
<5 years; 1 to 2 years
Unit Cost
$24,500.00
Maintenance Cost
$600 to $1,500
Tested For Chemical Agents
GB, VX, GA, GD, GF, AC, CG, HD, L, HN, CL2
Tested For ITF-25 TIC/TIMs
Chlorine, HCN, HCl, SO2, arsine
Tested For Explosives
No
Tested For Narcotics
No
Other Chemical Targets
Riot control agents, toluene 2,4-diisocyanate, toluene 2,6-diisocyanate
Adaptability
Yes, user can add new targets to detector with support using optional RAID-NT control software
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Known Interferents/Inhibitors
Typical interferents for IMS detector, including JP-8, gasoline, floor wax, Windex, aromatic vapors, smoke, cleaning compounds.
Start Up Time (From Cold Start To Sample Ready)
1 to 5 minutes
Response Time (Sample Application To Output)
<1 minute
Alarm Capability
Audible and visual
Software Control
XIMS-NT software
Other Operational Parameters
Automatic purge mode to prevent saturation and achieve fast recovery time. Gamma radiation detector
Training Required
<1 day training
Training Available
Yes
Manuals Available
Operator’s manual
Warranties
1 year factory warranty. Extended warranties at 5% per year up to 5 years.
ITAR/EAR Export Regulations
Yes; U.S. Nuclear Regulatory Agency regulations due to 63Nickel source
IATA Shipping Restrictions
Yes; U.S. Nuclear Regulatory Agency regulations due to 63Nickel source.