µRAIDplus

The µRAIDplus is a compact IMS-based chemical agent detector for personal monitoring.

Notify me on updates of this product 

Availability: Commercially Available

Frank Thibodeau
Vice President of Business Development
frank.thibodeau@brukerdetection.us
+1 978 663 3660
40 Manning Road
Billerica, MA 01821
USA
Bruker Daltonics, Inc.
www.bruker.com
Manufacturer
Bruker Corporation
Product Name
µRAIDplus
Detection Category
Chemical; Explosives;
Detection Principle
Spectrometry;
Detection Method
Ion Mobility Spectrometry ;
Application
Emergency Response; Gas Analysis; Bulk Analysis; Screening;
Equipment Type
Instrument
Product Synopsis
The µRAIDplus is a compact IMS-based chemical agent detector for personal monitoring.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
tooltip-iconAssociated Scoring Levels4 –TRL 9, immediately available
3 – TRL 9 1-2 months delivery after order
2 – TRL 7-8
1 – <TRL 7
Dimensions
5.1 x 2.5 x 8.8 in (130 x 64 x 223 mm)
Weight
<5 lbs.; 2.6 lbs (1.2 kg)
tooltip-iconAssociated Scoring Levels4 – <1 lb
3 – <5 Lbs.
2 – <30 Lbs.
1 – >30 Lbs.
Power Requirements
Lithium Battery; AC/DC Line Power; battery or 90-264 volt AC or 10-32 volt DC
tooltip-iconAssociated Scoring Levels4 – None
3 – Battery or Line Power
2 – Standard Line Power
1 – Non-Standard Line Power
Transportability
Handheld
tooltip-iconAssociated Scoring Levels4 – Handheld
3 – Person-Portable
2 – Mounted
1 – Benchtop/Fixed
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; Vibration/Shock; MIL-STD 810F, 461F, EN61000, EN61326-1, IEC 60529, 61010-1, IP65.
Operating Conditions
-32 to 53 °C (-26 to 127 °F); Altitude range: 400-1400 mBar ambient pressure range ~7,000 m / 21,000 ft; climb/descent rate: <10 m/s
Consumables
None
tooltip-iconAssociated Scoring Levels4 – No consumables or routine maintenance
3 – Minor consumables (< $1,000/year) and user maintenance
2 – Major consumables (> $1,000/year) and annual vendor provided maintenance
1 – Frequent Service/Manufacturer maintenance required
Communications Interface
Bluetooth data access
Expected Operational Life
1 to 2 years
Shelf Life
<5 years; 1 to 2 years
Unit Cost
$15,000.00
tooltip-iconAssociated Scoring Levels4 - <$500
3 – <$10,000 per unit
2 – <$50,000 per unit
1 – >$50,000 per unit
Tested For Chemical Agents
CWA: GA, GB, GD, GF, VX, HD, HN, L, HCN TICs: CL2, SO2, chlorinated substances, CLX, CY.
Tested For ITF-25 TIC/TIMs
CI2, SO2, Chlorinated Substances, CLX, Phosgene (CG),
Tested For Explosives
TDI, CY
Other Chemical Targets
Yes
Number of Library Entries
Five libraries are available, including a high-sensitivity CWA library.
Adaptability
New targets may be custom-programmed by the vendor.
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm; ppb
tooltip-iconAssociated Scoring Levels4 – Detects trace (<µg/ppm)
3 – Detects less than 1% in mixture
2 – Detects < ~10% in mixture
1 – Detects at > 10%
Start Up Time (From Cold Start To Sample Ready)
Minutes; temperature dependent.
Response Time (Sample Application To Output)
Continuous (<30 seconds)
tooltip-iconAssociated Scoring Levels4 – Continuous/<60 Seconds
3 – <5 minute
2 – <15 minute
1 – > 15 minutes
Total Run Time
< 1 minute
Alarm Capability
Yes
Software Control
Yes
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Warranties
1 year
IATA Shipping Restrictions
No
tooltip-iconAssociated Scoring Levels4 – Unregulated
3 – Ground and Cargo Air Only
2 – Ground Only
1 – IATA/DOT Certification Required/Hazardous Materials
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: