GDA-FR
The GDA-FR is able to detect and identify a broad variety of chemical substances in the range ppm - ppb.
Imbedded within the GDA-FR are: an ion mobility spectrometer (IMS), a photoionization detector (PID), two semiconductor gas sensors (MOS) and an electrochemical cell (EC).
Availability: Commercially Available
Cindy Siggelkow
+49 385 3993 276
Hagenower Straße 73
19061 Schwerin
Germany
|
|
www.airsense.com
| Manufacturer |
| Airsense Analytics |
| Product Name |
| GDA-FR |
| Detection Category |
| Chemical; |
| Detection Principle |
| Spectrometry; Sensors; |
| Detection Method |
| Ion Mobility Spectrometry; Photoionization Detection; Electrochemical Detection; Metal Oxide Semiconductor; |
| Application |
| Emergency Response; Gas Analysis; |
| Product Model Number |
| GDA-FR |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The GDA-FR is able to detect and identify a broad variety of chemical substances in the range ppm - ppb.
Imbedded within the GDA-FR are: an ion mobility spectrometer (IMS), a photoionization detector (PID), two semiconductor gas sensors (MOS) and an electrochemical cell (EC). |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 15.7 x 4.5 x 8.4 in (395 x 112 x 210 mm) |
| Weight |
| <10 lbs.; 4.2 kg (8.4 lbs) |
| Power Requirements |
| AC/DC Line Power; 30W, powered by rechargeable battery and/or power supply (serial port – RS-232) |
| Transportability |
| Handheld |
| Ruggedness |
| None |
| Consumables |
| None |
| Solvents/Reagents |
| None |
| Available Accessories |
| WLAN & GPS, Geiger counter (X-ray and gamma detector) |
| Data Analysis Support Equipment |
| Windows XP, Vista, Windows 7, WinMuster GDA |
| Communications Interface |
| Serial port RS-232 |
| Shelf Life |
| >5 years |
| Maintenance Cost |
| Minimal |
| Tested For Chemical Agents |
| GA, GB, GD, GF, V, HD, HN, L, AC |
| Tested For ITF-25 TIC/TIMs |
| Yes |
| Tested For Explosives |
| No |
| Tested For Narcotics |
| No |
| Other Chemical Targets |
| Yes |
| Adaptability |
| Yes; manufacturer can add new targets to detector |
| Sample Introduction |
| Vapor/Gas |
| Sensitivity/Detection Limits |
| ppb; ppm |
| Response Time (Sample Application To Output) |
| <1 minute |
| Total Run Time |
| <1 minute |
| Alarm Capability |
| Audible and visual |
| Software Control |
| On-board, Remote |
| Training Required |
| <1 day training |
| Training Available |
| Yes |
| Manuals Available |
| Yes |
| IATA Shipping Restrictions |
| No |