PanNAT System

PanNAT molecular diagnostic system is a point of care instrument capable of processing distinct cartridges, each designed to perform a single and /or multiplexed nucleic acid amplification assay.  Each assay is fully integrated into the disposable cartridge that includes all necessary reagents. Only a small volume of biological sample is required for assay performance.

Notify me on updates of this product 

Availability: DISCONTINUED

Manufacturer
Micronics
Product Name
PanNAT System
Detection Category
Biological
Detection Principle
Molecular;
Detection Method
Polymerase Chain Reaction;
Application
Detection; Laboratory Analysis;
Equipment Type
Instrument
Product Synopsis
PanNAT molecular diagnostic system is a point of care instrument capable of processing distinct cartridges, each designed to perform a single and /or multiplexed nucleic acid amplification assay.  Each assay is fully integrated into the disposable cartridge that includes all necessary reagents. Only a small volume of biological sample is required for assay performance.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
8
User Feedback Sources
Indifferent/No user feedback
Dimensions
12 x 15 x 12 in (30.5 x 38 x 30.5 cm)
Weight
<30 lbs.; 24 lbs ( 11kg)
Power Requirements
AC/DC Line Power; 110/220 v
Transportability
Person-Portable
Operating Conditions
4 to 41 °C (39 to 106 °F)
Consumables
<$1,000/year; Swab, buffer tube, adaptor cap, cartridge
Solvents/Reagents
Buffer
Suggested Routine Maintenance
In Development
Available Accessories
Printer
Communications Interface
Wi-Fi, USB
Expected Operational Life
In Development
Shelf Life
<5 years; 2 years
Unit Cost
Not available; in development
Maintenance Cost
In Development
Tested For Biological Agents
Shiga-toxin producing E. coli (STEC) and other enteric pathogens
Other Biological Targets
STDs; respiratory pathogens; HAIs; and other bacterial & viral pathogens
Number of Library Entries
In Development
Sample Introduction
Liquid
Sensitivity/Detection Limits
cfu/mL; 100 to 1,000 CFU/mL
Known Interferents/Inhibitors
In Development
False Positive Rates
In Development
False Negative Rates
In Development
Start Up Time (From Cold Start To Sample Ready)
< 5 minutes
Response Time (Sample Application To Output)
<15 minutes
Total Run Time
1 hour
Alarm Capability
No
Software Control
On-board
Other Operational Parameters
9 channels, internal storage up to 1,000 results
Training Required
<1 day training
Training Available
Yes
Manuals Available
User's Manual
Data File Type Format
LIS/HIS
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: