zNose Series

The Model 4300 zNose is a fully portable GC/SAW that can detect and analyze all types of vapors and identify traces of organic and chemical compounds quickly and accurately. It is designed with an internal helium cylinder (refillable), and can adapt to use disposable helium cylinders. The lithium ion battery is rechargeable, typically lasting 6 hours. The 4300 and 7100 models provide more quantitative results than the 4600, but require an external computer. The 7100 model is not portable.

Notify me on updates of this product 

Availability: Commercially available

Ken Zeiger
kzeiger@estcal.com
+1 805 214 1520
1077 Business Center Drive
Newbury Park, CA 91320
USA
www.estcal.com
Manufacturer
Electronic Sensor Technology, Inc.
Product Name
zNose Series
Detection Category
Chemical; Explosives
Detection Principle
Chromatography; Sensors;
Detection Method
Surface Acoustic Wave Detection;
Application
Emergency Response; Gas Analysis; Screening; Bulk Analysis;
Product Model Number
4200, 4300, 4600, 7100
Equipment Type
Instrument
Product Synopsis
The Model 4300 zNose is a fully portable GC/SAW that can detect and analyze all types of vapors and identify traces of organic and chemical compounds quickly and accurately. It is designed with an internal helium cylinder (refillable), and can adapt to use disposable helium cylinders. The lithium ion battery is rechargeable, typically lasting 6 hours. The 4300 and 7100 models provide more quantitative results than the 4600, but require an external computer. The 7100 model is not portable.
Availability
Commercially available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
Head: 12.5 x 4.3 x 6.8 in (318 x 110 x 173 mm) Support: 12.5 x 9.7 x 5.8 in (318 x 247 x 148 mm) Charger: 13.5 x 9.7 x 3.7 in (343 x 247 x 94 mm)
Weight
<50 lbs.; Head: 5.7 lbs (2.6 kg) Support: 18.7 lbs (8.5 kg) Charger: 7.7 lbs ( 3.5 kg)
Power Requirements
Lithium Battery; AC/DC Line Power; Fuse: 4 amp, 250 V AC Battery Pack (4300 only): 28 V DC, 16 A Lithium-ion battery (6 hour use typical)
Transportability
Person-Portable
Ruggedness
None
Operating Conditions
0 to 40°C (32 to 105°F); 0 to 95%RH, non-condensing
Consumables
>$1,000/year; Helium; Purge Dryer Refill; Purge Dryer Cartridge Kit; 1 µL syringe; Performance Evaluation Kit VOC (C6 – C14)
Calibration Schedule
Yes
Suggested Routine Maintenance
Occasional column replacement
Available Accessories
Shipping case; Battery Assembly; DC/AC Inverter; Battery Charger
Data Analysis Support Equipment
Laptop or PC
Communications Interface
RS-232 between controller and 4300 Bluetooth
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$30,000.00
Maintenance Cost
Annual PM $4,300; Replacement column $995; Validation service: $1,495
Tested For Chemical Agents
GB and GD
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
TNT, TATP, C4, NG
Other Chemical Targets
Volatile chemicals
Adaptability
Yes; manufacturer can add new targets to detector
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppb
Known Interferents/Inhibitors
Gas chromatograph separates CAs from most interferents
Start Up Time (From Cold Start To Sample Ready)
15 minutes
Response Time (Sample Application To Output)
<1 minute; 5 to 60 seconds
Total Run Time
< 25 minutes
Alarm Capability
Audible and visual
Software Control
Product software needs an Intel Pentium 100 MHz or better processor with a minimum of 16 MB RAM, a 1GB Hard Drive, and any version of Microsoft Windows
Training Required
<1 week training
Training Available
Yes, classroom training for one student $2,400
Manuals Available
Yes
Warranties
1 year: parts only Hardware: 180 days for parts and labor Software: 180 days
IATA Shipping Restrictions
Yes; Shipment of gas is by ground only
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: