Chemical Sensor Array (CSA) Series

The CSA uses BPSI’s patented Electro-Chemical sensor technology aligned in N+1 redundant configuration for detection of target chemicals providing real time monitoring There are three models; extended (E), SMART (S) and next generation (X). The S is for simple plug-in to resident Automation Systems and the X for direct connection to the Sentry One™ system or to the Cloud.

Notify me on updates of this product 

Availability: Commercially Available

+1 888 888 BPSI
150 Post Street Suite 750
San Francisco, CA 94108
www.BPSIglobal.com
Manufacturer
Building Protection Systems, Inc.
Product Name
Chemical Sensor Array (CSA) Series
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Electrochemical Detection;
Application
Emergency Response; Gas Analysis & Air Monitoring; Sample Collection; Screening ;
Product Model Number
E-CSA, X-CSA, S-SCA
Equipment Type
Instrument
Product Synopsis
The CSA uses BPSI’s patented Electro-Chemical sensor technology aligned in N+1 redundant configuration for detection of target chemicals providing real time monitoring There are three models; extended (E), SMART (S) and next generation (X). The S is for simple plug-in to resident Automation Systems and the X for direct connection to the Sentry One™ system or to the Cloud.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
16 x 20 x 6 in (40.6 x 50.7 x 15.2 cm)
Weight
<50 lbs.; 40 lbs. (18.6 kg)
Power Requirements
AC/DC Line Power; Selectable: 120-240/1/50-60 Hz 1.0 Amp
Transportability
Mounted
Operating Conditions
0 to 45°C (32 to 113°F)
Consumables
<$1,000/year; Filters; Sensors
Calibration Schedule
No Field Calibration; Automatic Continuous w/ self calibration features for drift and temperature
Suggested Routine Maintenance
Simple semi-annual to bi-annual filter changes and a sensor swap at 48 months
Data Analysis Support Equipment
Remote Automation System
Communications Interface
Ethernet or fiber optic connection (E, X) Modbus (S, X), Cloud, PLC (X)
Shelf Life
>5 years
Tested For Chemical Agents
No
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
No
Tested For Narcotics
No
Other Chemical Targets
No
Number of Library Entries
38 toxic chemical gasses
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
False Positive Rates
< 0.005%
False Negative Rates
< 0.005%
Start Up Time (From Cold Start To Sample Ready)
30 to 60 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous
Alarm Capability
No
Software Control
Yes
Training Required
<1 week training
Training Available
Yes
Manuals Available
User's manual
Please enter contact info.