identiFINDER® R500

The FLIR identiFINDER R500 is capable of locating and identifying radioactive material in difficult monitoring scenarios. Like other identiFINDER R-series products, the R500 contains on-board Bluetooth®, web server, and GPS technologies.

Notify me on updates of this product 

Availability: Discontinued

Toby Kennedy
DoD Sales and BD Manager
toby.kennedy@teledyneflir.com
580-761-7200
27729 SW Parkway Avenue
Wilsonville, OR 97099
The Americas, EMEA, APAC
Contact for pricing, availability and 3rd party vendors
https://www.flir.com/browse/government-defense/cbrne-detectors/
Manufacturer
Teledyne FLIR Detection, Inc.
Product Name
identiFINDER® R500
Detection Category
Radiological/Nuclear;
Detection Principle
Scintillation Detectors; Geiger-Muller Detectors; Helium 3 Detectors;
Detection Method
Scintillation Detectors; Geiger-Muller Detectors; Helium 3 Detectors;
Application
Identifiers; Port Screening; Survey Meter;
Equipment Type
Instrument
Product Synopsis
The FLIR identiFINDER R500 is capable of locating and identifying radioactive material in difficult monitoring scenarios. Like other identiFINDER R-series products, the R500 contains on-board Bluetooth®, web server, and GPS technologies.
Availability
Discontinued
Technology Readiness Level (TRL)
9
Market Entry Date
2011
User Feedback Sources
Indifferent/No user feedback
Dimensions
5.1 x 8.3 x 12.7 in (129 x 21 2x 323 mm)
Weight
<30 Lbs.; NaI: 6.4 Lbs. (2.9 kg) LaBr3: 5 Lbs. (2.4 kg)
Power Requirements
NiMH Battery; AC/DC Line Power; 100 to 240 VAC or LSD NiMH battery (8 hours)
Transportability
Handheld
Ruggedness
Dust; Waterproof/Resistant; Aluminum housing; protection rating IP54 according to IEC 60529
Operating Conditions
–20 to 50°C (-4 to 122°F), 10 to 80% RH
Consumables
None
Calibration Schedule
Automatic calibration on start up
Suggested Routine Maintenance
5 year factory maintenance
Available Accessories
None
Communications Interface
USB 2.0; mini-B socket; Bluetooth® Class 2.0, 10m range (removable)
Expected Operational Life
10+ years
Shelf Life
>5 years
Unit Cost
$19,000 to $37,000
Maintenance Cost
None
Radiological Targets
Yes
Number of Library Entries
ANSI N42.34
Adaptability
No; cannot detect or add new targets
Sample Introduction
Vapor/Gas; Radioactive Particle
Sensitivity/Detection Limits
cps; Neutron sensitivity: 9 cps/nv; ±15 %
Start Up Time (From Cold Start To Sample Ready)
< 2 mins from cold start
Response Time (Sample Application To Output)
<5 minutes; From a few seconds to minutes
Total Run Time
Continuous
Alarm Capability
Audible and visual
Software Control
On-board webserver software
Training Required
<1 day training
Training Available
<10 mins for operator; 1 day for advanced user
Manuals Available
Yes
Reachback Service
Yes - OneTouch Reachback
Warranties
Yes
ITAR/EAR Export Regulations
Yes; These products are controlled for export under US Department of Commerce (DOC), Export Administration Regulations (EAR). U.S. Government authorization may be required.
Approved Vendors
Federal Resources
Data File Type Format
2GB internal memory; up to 600,000 spectra; n42.42 file format
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: