identiFINDER® R200
The FLIR identiFINDER R200 is a rugged, pager-sized Spectroscopic Personal Radiation Detector (SPRD). It provides full ANSI N42.32 Personal Radiation Detector (PRD) compliance and features solid state detector read-out that delivers ANSI N42.48 SPRD compliance with nuclide identification. The OneTouch Reachback™ feature uses Bluetooth® and web server technologies to provide large-scale situational awareness by alerting others before arriving on-scene.
Availability: Discontinued
| Manufacturer |
| Teledyne FLIR Detection, Inc. |
| Product Name |
| identiFINDER® R200 |
| Detection Category |
| Radiological/Nuclear; |
| Detection Principle |
| Scintillation Detectors; |
| Detection Method |
| Scintillation Detectors; |
| Application |
| Identifiers; Personal Radiation Detectors; |
| Product Model Number |
| R200 |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The FLIR identiFINDER R200 is a rugged, pager-sized Spectroscopic Personal Radiation Detector (SPRD). It provides full ANSI N42.32 Personal Radiation Detector (PRD) compliance and features solid state detector read-out that delivers ANSI N42.48 SPRD compliance with nuclide identification. The OneTouch Reachback™ feature uses Bluetooth® and web server technologies to provide large-scale situational awareness by alerting others before arriving on-scene. |
| Availability |
| Discontinued |
| Technology Readiness Level (TRL) |
| 9 |
| Market Entry Date |
| 2015 |
| User Feedback Sources |
| Hands-on experience |
| Dimensions |
| 5.7 x 2.2 x 1.9 in (14.5 x 5.6 x 4.8 cm) with battery |
| Weight |
| <1 Lb.; 0.88 Lbs. (0.4 kg) |
| Power Requirements |
| Lithium Battery; AC/DC Line Power; Li-ion (36 hours); 6 hour recharge time when using AC or USB power source |
| Transportability |
| Pocket Size |
| Ruggedness |
| Extreme Temperatures/Humidity; Dust; Waterproof/Resistant; Wearable and rugged (1.5-m drop tested); Plastic with rubber overmold; protection rating IP67 according to IEC 60529 |
| Operating Conditions |
| –20 to 50°C (-4 to 122°F), 93% RH |
| Consumables |
| None |
| Calibration Schedule |
| Annual dose rate calibration |
| Suggested Routine Maintenance |
| 5 year factory maintenance |
| Communications Interface |
| USB 2.0; mini-B socket; Bluetooth® 10m range (removable) |
| Expected Operational Life |
| 5 years |
| Shelf Life |
| >5 years |
| Unit Cost |
| $2,800.00 |
| Maintenance Cost |
| None |
| Radiological Targets |
| Yes |
| Number of Library Entries |
| ANSI N42.48 |
| Adaptability |
| No; cannot detect or add new targets |
| Sample Introduction |
| Vapor/Gas; Radioactive Particle |
| Sensitivity/Detection Limits |
| µSv; Dose rate: 100 nSv/h to 250 µSv/h (10µRem/h to 25 mRem/h) |
| Start Up Time (From Cold Start To Sample Ready) |
| < 2 mins |
| Response Time (Sample Application To Output) |
| <5 minutes; From a few seconds to minutes |
| Total Run Time |
| Continuous |
| Alarm Capability |
| Memory LCD black and white display |
| Software Control |
| On-board webserver software |
| Other Operational Parameters |
| Resolution: 7.5 % FWHM at 662 keV; Energy range: 25 keV to 3 MeV |
| Training Required |
| <1 day training |
| Training Available |
| < 10 mins for operator; a few hours for train the trainer |
| Manuals Available |
| Yes |
| Reachback Service |
| Yes - OneTouch Reachback |
| Warranties |
| Yes |
| ITAR/EAR Export Regulations |
| Yes; These products are controlled for export under US Department of Commerce (DOC), Export Administration Regulations (EAR). U.S. Government authorization may be required. |
| IATA Shipping Restrictions |
| No |
| Approved Vendors |
| Federal Resources |
| Data File Type Format |
| 30MB internal memory; up to 5000 spectra |