RayMon10™
The RayMon10™ is a handheld radiation monitor. It can be used to detect, measure and identify gamma ray emitting radio nuclides, providing high-resolution isotope identification using CZT coplanar grid detector technology.
Availability: Commercially Available
| Manufacturer |
| Kromek Group plc |
| Product Name |
| RayMon10™ |
| Detection Category |
| Radiological/Nuclear; |
| Detection Principle |
| Semiconductors; |
| Detection Method |
| Semiconductors; |
| Application |
| Identifiers;Personal Radiation Detectors; |
| Product Model Number |
| RayMon10 |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The RayMon10™ is a handheld radiation monitor. It can be used to detect, measure and identify gamma ray emitting radio nuclides, providing high-resolution isotope identification using CZT coplanar grid detector technology. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Supporting Documentation |
| Docs: Kromek-RayMon10.pdf; |
| Dimensions |
| PDA Unit: 7 x 7.6 x 6 in (17.6 x 19.2 x 15.0 cm); Probe + Cable: 9.4 x 1.8 x 1.8 in (24 x 4.5 x 4.5 cm) |
| Weight |
| <5 lbs.; PDA Unit: 1.69 lbs (769 g); Probe + Cable: 0.6 lbs (252 g) |
| Power Requirements |
| Lithium Battery; 5000 mAh rechargeable (8 hours) |
| Transportability |
| Handheld |
| Ruggedness |
| Extreme Temperatures/Humidity |
| Operating Conditions |
| -30 to 60°C (-22 to 140°F); 90% RH |
| Consumables |
| None |
| Calibration Schedule |
| Yes |
| Available Accessories |
| Extra battery pack; 12 volt in-car charger; 5MP camera module; 3G cellular network module |
| Data Analysis Support Equipment |
| PC running Windows-based (7/8) |
| Communications Interface |
| USB; Bluetooth |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Unit Cost |
| $16,000.00 |
| Radiological Targets |
| Gamma |
| Number of Library Entries |
| 94 radionuclides |
| Adaptability |
| Yes; manufacturer can add new targets to detector |
| Sample Introduction |
| Radioactive Particle |
| Sensitivity/Detection Limits |
| CPS |
| Start Up Time (From Cold Start To Sample Ready) |
| Seconds to minutes |
| Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
| Total Run Time |
| Variable; < 1 min, < 10 min, < 1 hour |
| Alarm Capability |
| Audible |
| Software Control |
| On-board, PC |
| Other Operational Parameters |
| Cadmium Zinc Telluride (CZT), Energy range: 60 keV to 3.0 Me; Energy resolution: 2.0-2.5% FWHM at 662 keV |
| Training Required |
| <1 day training |
| Training Available |
| No |
| Manuals Available |
| User's Manual |
| Reachback Service |
| Yes |
| Warranties |
| 1 year |
| IATA Shipping Restrictions |
| Yes, Li-ion battery |
| Data File Type Format |
| SPE, CSV, PDF |