Quant Air

The Quant Air system incorporates an optimized lead/copper shield enabling operation in both standard and raised backgrounds. This enables monitoring of potential activity build up and acts as a live warning system, allowing remedial actions to be carried out at the time of release. This minimizes potential intake and increases worker safety.

Notify me on updates of this product 

Availability: Commercially Available

sales@kromek.com
+44 1740 626060
NETPark, Thomas Wright Way
Durham TS21 3FD
UK
Trevor Nicholls
Director of Sales and Marketing
trevor.nicholls@kromek.com
USA
www.kromek.com/index.php/products/quant-air
www.kromek.com
Manufacturer
Kromek Group plc
Product Name
Quant Air
Detection Category
Radiological/Nuclear
Detection Principle
Semiconductors;
Detection Method
Semiconductors;
Application
Identifiers;
Equipment Type
Instrument
Product Synopsis
The Quant Air system incorporates an optimized lead/copper shield enabling operation in both standard and raised backgrounds. This enables monitoring of potential activity build up and acts as a live warning system, allowing remedial actions to be carried out at the time of release. This minimizes potential intake and increases worker safety.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
9 x 4 x 3 in ( 219.5 x 113.3 x 62.5 mm)
Weight
<30 lbs.; 10.6 lbs (4.8 kg)
Power Requirements
AC/DC Line Power; Powered via USB
Transportability
Person-Portable
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP65 and MIL-STD-810G
Operating Conditions
-30 to 60°C (-22 to 140°F); 90% RH
Consumables
None
Calibration Schedule
Yes
Available Accessories
Vehicle Mount or Dock
Data Analysis Support Equipment
PC running Windows-based (7/8)
Communications Interface
USB
Shelf Life
>5 years
Radiological Targets
Gamma
Adaptability
Yes; user can add new targets to detector with support
Sample Introduction
Radioactive Particle
Start Up Time (From Cold Start To Sample Ready)
Seconds to minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous
Alarm Capability
Audible and visual
Software Control
On-board, PC
Other Operational Parameters
Cadmium Zinc Telluride (CZT), Adjustable confidence levels, Energy range: 30 keV to 3.0 MeV
Training Required
<1 day training
Training Available
No
Manuals Available
User's Manual
Warranties
1 year
Data File Type Format
CSV
Please enter contact info.
Email Address: 
Company: 
Name: 