Quant Air
The Quant Air system incorporates an optimized lead/copper shield enabling operation in both standard and raised backgrounds. This enables monitoring of potential activity build up and acts as a live warning system, allowing remedial actions to be carried out at the time of release. This minimizes potential intake and increases worker safety.
Availability: Commercially Available
| Manufacturer |
| Kromek Group plc |
| Product Name |
| Quant Air |
| Detection Category |
| Radiological/Nuclear |
| Detection Principle |
| Semiconductors; |
| Detection Method |
| Semiconductors; |
| Application |
| Identifiers; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The Quant Air system incorporates an optimized lead/copper shield enabling operation in both standard and raised backgrounds. This enables monitoring of potential activity build up and acts as a live warning system, allowing remedial actions to be carried out at the time of release. This minimizes potential intake and increases worker safety. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 9 x 4 x 3 in ( 219.5 x 113.3 x 62.5 mm) |
| Weight |
| <30 lbs.; 10.6 lbs (4.8 kg) |
| Power Requirements |
| AC/DC Line Power; Powered via USB |
| Transportability |
| Person-Portable |
| Ruggedness |
| Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; IP65 and MIL-STD-810G |
| Operating Conditions |
| -30 to 60°C (-22 to 140°F); 90% RH |
| Consumables |
| None |
| Calibration Schedule |
| Yes |
| Available Accessories |
| Vehicle Mount or Dock |
| Data Analysis Support Equipment |
| PC running Windows-based (7/8) |
| Communications Interface |
| USB |
| Shelf Life |
| >5 years |
| Radiological Targets |
| Gamma |
| Adaptability |
| Yes; user can add new targets to detector with support |
| Sample Introduction |
| Radioactive Particle |
| Start Up Time (From Cold Start To Sample Ready) |
| Seconds to minutes |
| Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
| Total Run Time |
| Continuous |
| Alarm Capability |
| Audible and visual |
| Software Control |
| On-board, PC |
| Other Operational Parameters |
| Cadmium Zinc Telluride (CZT), Adjustable confidence levels, Energy range: 30 keV to 3.0 MeV |
| Training Required |
| <1 day training |
| Training Available |
| No |
| Manuals Available |
| User's Manual |
| Warranties |
| 1 year |
| Data File Type Format |
| CSV |