DR3900
The DR3900 is a benchtop visible spectrum (320 - 1100 nm), split beam spectrophotometer with over 220 pre-programmed methods optimized for laboratory water analysis
Availability: Commercially Available
| Manufacturer |
| Hach |
| Product Name |
| DR3900 |
| Detection Category |
| Chemical; Biological |
| Detection Principle |
| Molecular Spectroscopy; |
| Detection Method |
| Ultraviolet-Visible; |
| Application |
| Bulk Analysis; Laboratory Analysis; Screening; Water Quality; |
| Product Model Number |
| LPV440.99.00012 |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The DR3900 is a benchtop visible spectrum (320 - 1100 nm), split beam spectrophotometer with over 220 pre-programmed methods optimized for laboratory water analysis |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Weight |
| <30 Lbs.; 9.2 Lbs. (4.2 kg) |
| Power Requirements |
| AC/DC Line Power |
| Transportability |
| Benchtop/Fixed; Small Footprint |
| Ruggedness |
| None |
| Operating Conditions |
| 10 to 40 °C (50 to 104 °F), <80% RH |
| Consumables |
| >$1,000/year; sample vials and reagents ~$70 per 25 tests. |
| Solvents/Reagents |
| TNTplus® vials use Dosicaps - freeze-dried reagents integrated into sealed cap - that are easier to use than Powder Pillows or Liquid Reagents, without any risk of contamination. |
| Calibration Schedule |
| Instrument calibration verification and high instrument stability all combine to eliminate the need to run reagent blanks. |
| Available Accessories |
| RFID technology, light shield, dust cover, printed basic user manual and benchtop power supply with 115 and 230V power cords. |
| Communications Interface |
| USB type A (2), USB type B, Ethernet, RFID module |
| Shelf Life |
| >5 years |
| Unit Cost |
| $6,000.00 |
| Maintenance Cost |
| Minimal |
| Other Chemical Targets |
| Ammonium, COD, phosphate, nitrate, arsenic, barium, boron, bromine, cadmium, chloride, chlorine dioxide, chlorine, chromium, cobalt, copper, cyanide, cyanuric acid, fluoride, formaldehyde. 200 chemicals in library. |
| Adaptability |
| No; cannot detect or add new targets |
| Sample Introduction |
| Liquid; Solid |
| Response Time (Sample Application To Output) |
| <15 minutes |
| Alarm Capability |
| None |
| Software Control |
| On-board; PC |
| Other Operational Parameters |
| Light source: Gas-filled Tungsten (visible). Wavelength: 320 - 1100 nm. For operation, the vial spins to take 10-fold absorbance readings that will be averaged for result determination to exclude scratches and fingerprints. |
| Training Required |
| <1 day training |
| Training Available |
| Yes |
| Manuals Available |
| Yes |
| Warranties |
| 12 month |