DR3900

The DR3900 is a benchtop visible spectrum (320 - 1100 nm), split beam spectrophotometer with over 220 pre-programmed methods optimized for laboratory water analysis

Notify me on updates of this product 

Availability: Commercially Available

Ellen Leboeuf
eleboeuf@hach.com
+1 800 227 4224
P.O. Box 389
Loveland, Colorado 80539-0389
www.hach.com/
www.hach.com/
Manufacturer
Hach
Product Name
DR3900
Detection Category
Chemical; Biological
Detection Principle
Molecular Spectroscopy;
Detection Method
Ultraviolet-Visible;
Application
Bulk Analysis; Laboratory Analysis; Screening; Water Quality;
Product Model Number
LPV440.99.00012
Equipment Type
Instrument
Product Synopsis
The DR3900 is a benchtop visible spectrum (320 - 1100 nm), split beam spectrophotometer with over 220 pre-programmed methods optimized for laboratory water analysis
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Weight
<30 Lbs.; 9.2 Lbs. (4.2 kg)
Power Requirements
AC/DC Line Power
Transportability
Benchtop/Fixed; Small Footprint
Ruggedness
None
Operating Conditions
10 to 40 °C (50 to 104 °F), <80% RH
Consumables
>$1,000/year; sample vials and reagents ~$70 per 25 tests.
Solvents/Reagents
TNTplus® vials use Dosicaps - freeze-dried reagents integrated into sealed cap - that are easier to use than Powder Pillows or Liquid Reagents, without any risk of contamination.
Calibration Schedule
Instrument calibration verification and high instrument stability all combine to eliminate the need to run reagent blanks.
Available Accessories
RFID technology, light shield, dust cover, printed basic user manual and benchtop power supply with 115 and 230V power cords.
Communications Interface
USB type A (2), USB type B, Ethernet, RFID module
Shelf Life
>5 years
Unit Cost
$6,000.00
Maintenance Cost
Minimal
Other Chemical Targets
Ammonium, COD, phosphate, nitrate, arsenic, barium, boron, bromine, cadmium, chloride, chlorine dioxide, chlorine, chromium, cobalt, copper, cyanide, cyanuric acid, fluoride, formaldehyde. 200 chemicals in library.
Adaptability
No; cannot detect or add new targets
Sample Introduction
Liquid; Solid
Response Time (Sample Application To Output)
<15 minutes
Alarm Capability
None
Software Control
On-board; PC
Other Operational Parameters
Light source: Gas-filled Tungsten (visible). Wavelength: 320 - 1100 nm. For operation, the vial spins to take 10-fold absorbance readings that will be averaged for result determination to exclude scratches and fingerprints.
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Warranties
12 month
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: