RI-215A

The RI-215A is a wall-mounted IR CO2 monitor for measurement and control of CO2 levels in fixed location applications. A non-dispersive infrared absorption sensor is used to provide direct measurements through diffusion, and to activate alarms or control ventilation systems based on preset CO2 levels. The RI-215A provides a digital readout in parts per million of CO2 providing precise measurement and direct visual indication of gas levels. A 4-20 mA output is provided to send a signal to a fire panel or other PLC system and a relay is available to trip an alarm or activate a ventilation system. Three levels of measurement are provided: 0-2,000 ppm (ASHRAE 1969 IAQ max PEL), 0-5,000 ppm (leak detection of CO2 storage tanks) and 0-9,999 ppm. The RI-215A runs on 24 VAC or 24 VDC and is designed for indoor use only and supplied in a NEMA 12 enclosure that is accessible for calibration, service, and continuous monitoring.

Notify me on updates of this product 

Availability: Commercially Available

Dave McEndarffer
Central Regional Sales Manager
dave@rkiinstruments.com
913-634-0396
33238 Central Avenue
Union City, CA 94578
USA
www.rkiinstruments.com
Manufacturer
RKI Instruments
Product Name
RI-215A
Detection Category
Chemical
Detection Principle
Molecular Spectroscopy;
Detection Method
Non-Dispersive Infrared (NDIR);
Application
Gas Analysis; Facility Monitoring;
Product Model Number
RI-215A
Equipment Type
Instrument
Product Synopsis
The RI-215A is a wall-mounted IR CO2 monitor for measurement and control of CO2 levels in fixed location applications. A non-dispersive infrared absorption sensor is used to provide direct measurements through diffusion, and to activate alarms or control ventilation systems based on preset CO2 levels. The RI-215A provides a digital readout in parts per million of CO2 providing precise measurement and direct visual indication of gas levels. A 4-20 mA output is provided to send a signal to a fire panel or other PLC system and a relay is available to trip an alarm or activate a ventilation system. Three levels of measurement are provided: 0-2,000 ppm (ASHRAE 1969 IAQ max PEL), 0-5,000 ppm (leak detection of CO2 storage tanks) and 0-9,999 ppm. The RI-215A runs on 24 VAC or 24 VDC and is designed for indoor use only and supplied in a NEMA 12 enclosure that is accessible for calibration, service, and continuous monitoring.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
3.1 x 3.1 x 1.2 in. (78 x 78 x 31 mm)
Weight
<1 lb.; 6.5 oz. (200 g)
Power Requirements
AC/DC Line Power; 24 VDC or VAC
Transportability
Benchtop/Fixed
Ruggedness
Indoor use only
Operating Conditions
0 to 40° C (32 to 104° F); 0 to 90% RH, non-condensing
Consumables
>$1,000/year; calibration gas, sensor
Solvents/Reagents
None
Calibration Schedule
Requires quarterly calibration
Suggested Routine Maintenance
Zero calibration, CO2 calibration
Data Analysis Support Equipment
No data logging capability; signal output is provided: 0-10 VDC linear (load resistance: Min. 300K ), or 4-20mADC linear (load resistance: Max. 500)
Shelf Life
>5 years
Unit Cost
$850.00
Maintenance Cost
$500/year (est.) for replacement sensor, filter disk, and calibration gases
Tested For ITF-25 TIC/TIMs
No
Tested For Explosives
No
Tested For Narcotics
No
Other Chemical Targets
Carbon dioxide in air
Tested For Biological Agents
No
Other Biological Targets
No
Radiological Targets
No
Adaptability
No; cannot detect or add new targets
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm; 0-2,000 ( ±1%); 0-5,000 ( ±3%); 0-9,900 ( ±10%)
Start Up Time (From Cold Start To Sample Ready)
30 minutes
Response Time (Sample Application To Output)
Continuous (<30 seconds)
Total Run Time
Continuous sampling
Alarm Capability
No
Software Control
No external control
Training Required
<1 day training
Training Available
No
Manuals Available
Yes
Warranties
2 years material and workmanship
Approved Vendors
Multiple