PGR-1064

The PGR-1064™ device is a handheld Raman chemical identifier that providing measurements for screening unknown substances.

Notify me on updates of this product 

Availability: Commercially Available

Mirela Popa
Director of Business Development
mpopa@chemringsensors.com
+1 980 235 2326
4205 Westinghouse Commons Drive
Charlotte, NC 28273
USA
info@chemringds.com
+1 980 235 2200
www.chemringds.com
Manufacturer
Chemring Detection Systems
Product Name
PGR-1064
Detection Category
Chemical; Explosives
Detection Principle
Molecular Spectroscopy;
Detection Method
Raman Spectroscopy;
Application
Emergency Response; Screening; Bulk Analysis;
Equipment Type
Instrument
Product Synopsis
The PGR-1064™ device is a handheld Raman chemical identifier that providing measurements for screening unknown substances.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Market Entry Date
2015
User Feedback Sources
MRIGlobal hands-on experience
Dimensions
2.5 x 7.5 x 6.6 in (6.4 x 19 x 16.7 cm)
Weight
<5 lbs.; 2.25 lbs (1.0 kg)
Power Requirements
Lithium Battery; AC/DC Line Power; Rechargeable Lithium Ion 3-cell pack, charger integrated into handheld; 10+ hours during typical operation at 25°C; Wall plug transformer 110-240 VAC 50/60 Hz
Transportability
Handheld
Ruggedness
Extreme Temperatures/Humidity; Waterproof/Resistant; Dust; Vibration/Shock; MIL STD 810G Method 514.6; Category 24 vibration testing
Operating Conditions
-20 to 40°C (-4 to 104°F)
Consumables
<$1,000/year; Sample vials, Sampling utensils
Calibration Schedule
No field calibration required
Data Analysis Support Equipment
Onboard; color transflective LCD screen; Joystick and trigger operation.
Communications Interface
USB
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$32,500.00
Tested For Chemical Agents
Amenable based on technology
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Yes
Tested For Narcotics
Yes, including fentanyl and 6 of its analogues
Other Chemical Targets
Yes
Number of Library Entries
5,000+
Adaptability
Yes; user can add new targets in the field
Sample Introduction
Solid; Liquid
Sensitivity/Detection Limits
Bulk; mg; g; %
Start Up Time (From Cold Start To Sample Ready)
<10 seconds
Response Time (Sample Application To Output)
Continuous (<30 seconds); < 10 seconds
Total Run Time
1 minute
Software Control
On board via color transflective LCD
Other Operational Parameters
Spectral Resolution: 8 cm-1 full-width at half-maximum (FWHM) across range; Laser (excitation wavelength):1064 nm +/- 0.5 nm, 2 cm-1 line with stability <0.1 cm-1
Training Required
<1 day training
Training Available
Training at customer or vendor facility
Manuals Available
Yes
Warranties
1 year parts and labor, extended warranties available up to 2 additional years.
IATA Shipping Restrictions
Yes; Lithium ion battery
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: