M256A1 Chemical Agent Detector Kit
The M256A1 Chemical Agent Detector Kit is colorimetric-based kit designed to detect blister, nerve, blood, and Lewisite agents. The kit consists of: A plastic carry case with Velcro closure, a booklet of M8 test paper sealed in a plastic bag. Attached instruction cards; 12 pouches containing the chemical agent detector samplers.
Availability: Commercially Available
| Manufacturer |
| Luxfer Magtech, Inc. |
| Product Name |
| M256A1 Chemical Agent Detector Kit |
| Detection Category |
| Chemical |
| Detection Principle |
| Colorimetric; |
| Detection Method |
| Colorimetric; |
| Application |
| Emergency Response; |
| Product Model Number |
| 36601: Single Kit , 36600: Case (24 Kits) |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The M256A1 Chemical Agent Detector Kit is colorimetric-based kit designed to detect blister, nerve, blood, and Lewisite agents. The kit consists of: A plastic carry case with Velcro closure, a booklet of M8 test paper sealed in a plastic bag. Attached instruction cards; 12 pouches containing the chemical agent detector samplers. |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 5.3 x 6.8 x 3 in (13.5 x 17.3 x 7.7 cm) |
| Weight |
| <1 lb.; 0.45 kg |
| Power Requirements |
| None |
| Transportability |
| Handheld |
| Operating Conditions |
| Designed to operate in harsh environments |
| Consumables |
| <$1,000/year; Sampler Detectors, M8 Paper |
| Available Accessories |
| M8 paper |
| Expected Operational Life |
| 5 years |
| Shelf Life |
| >5 years |
| Unit Cost |
| $160.00 Single Kit |
| Tested For Chemical Agents |
| GA, GB, GD, VX, H, HD, HN |
| Tested For ITF-25 TIC/TIMs |
| Hydrogen cyanide and cyanogen chloride |
| Sample Introduction |
| Vapor/Gas; Liquid |
| Sensitivity/Detection Limits |
| ppm |
| Known Interferents/Inhibitors |
| Some smokes, high temperatures, DS2, and petroleum products may cause false readings |
| Start Up Time (From Cold Start To Sample Ready) |
| 1 to 5 minutes |
| Response Time (Sample Application To Output) |
| >15 minutes; 20 to 25 minutes |
| Total Run Time |
| 20 to 30 minutes |
| Training Required |
| <1 hour training |
| Training Available |
| A minimum of 4 to 6 hours of performance-oriented training is recommended. |
| Manuals Available |
| Instructions are printed on each sampler/detector ticket pouch. A detailed instruction card is attached to each carrying case with waxed cord. |
| Reachback Service |
| No |