RapID™
RapID uses Cobalt’s Spatially Offset Raman Spectroscopy (SORS™) technology, which is a Raman technique for non-invasive analysis of materials through packaging. RapID also meets the stringent requirements of current good manufacturing practices (cGMP) and 21 CFR Part 11 compliant environments. RapID™ is the next generation in high-throughput raw materials ID verification, allowing Raman identification through non-transparent and colored containers – even multi-layer paper and plastic sacks.
Availability: Commercially Available: >90 days for delivery
| Manufacturer |
| Agilent Technologies |
| Product Name |
| RapID™ |
| Detection Category |
| Chemical; Explosives |
| Detection Principle |
| Molecular Spectroscopy; |
| Detection Method |
| Raman Spectroscopy; Spatially Offset Raman Spectroscopy (SORS) ; |
| Application |
| Laboratory Analysis; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| RapID uses Cobalt’s Spatially Offset Raman Spectroscopy (SORS™) technology, which is a Raman technique for non-invasive analysis of materials through packaging. RapID also meets the stringent requirements of current good manufacturing practices (cGMP) and 21 CFR Part 11 compliant environments. RapID™ is the next generation in high-throughput raw materials ID verification, allowing Raman identification through non-transparent and colored containers – even multi-layer paper and plastic sacks. |
| Availability |
| Commercially Available: >90 days for delivery |
| Technology Readiness Level (TRL) |
| 9 |
| Market Entry Date |
| 2011 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 15.5 x 27 x 25 in (39.4 x 69.3 x 63 cm) |
| Weight |
| >50 lbs.; 103.6 lbs (47 kg) |
| Power Requirements |
| AC/DC Line Power; 90 to 132 / 180 to 264 VAC, 47 to 63 Hz |
| Noise Produced |
| None |
| Transportability |
| Person-Portable |
| Ruggedness |
| Extreme Temperatures/Humidity |
| Operating Conditions |
| 15 to 25°C (-4 to 122°F); < 70% RH non-condensing |
| Consumables |
| None |
| Calibration Schedule |
| Yes |
| Suggested Routine Maintenance |
| Minimal |
| Available Accessories |
| Workstation Adaptation; Nozzle Attachments, HDPE pot |
| Data Analysis Support Equipment |
| RapID software, Windows 7 Pro OS, 21 CFR Part 11 compliant |
| Communications Interface |
| RJ45, Wi-Fi, and USB 2.0 (plus optional VGA) |
| Expected Operational Life |
| Indefinite |
| Shelf Life |
| >5 years |
| Unit Cost |
| $50,000.00 |
| Tested For Chemical Agents |
| Amenable based on technology |
| Tested For ITF-25 TIC/TIMs |
| Amenable based on technology |
| Tested For Explosives |
| Amenable based on technology |
| Tested For Narcotics |
| Amenable based on technology |
| Other Chemical Targets |
| Sugars like mannitol, lactose, dextrose, glucose; Mcc, HPMC, Croscarmellose sodium; Acetaminophen; Magnesium stearate; API's; Sterile liquids; Salts; Amino Acids; Buffers; Polysorbates; Others |
| Number of Library Entries |
| Continuously updated libraries are available including a narcotics library |
| Adaptability |
| Yes; user can add new targets to detector with support |
| Sample Introduction |
| Solid; Liquid |
| Sensitivity/Detection Limits |
| ~10% |
| False Positive Rates |
| <1% |
| False Negative Rates |
| <1% |
| Start Up Time (From Cold Start To Sample Ready) |
| < 5 minutes |
| Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
| Total Run Time |
| < 15 minutes |
| Software Control |
| On-board |
| Other Operational Parameters |
| Class 3B Laser, 830nm |
| Training Required |
| <1 day training |
| Training Available |
| Yes, 1 day |
| Manuals Available |
| User's manual |
| Warranties |
| 1 year standard, extended warranties also available |
| IATA Shipping Restrictions |
| No |
| Data File Type Format |
| CSV, SPC, PDF |