Direct Reading Pocket Dosimeters
The Direct-Reading Dosimeters are designed to measure and directly read, at any time accumulated dose of gamma and x-ray radiation exposure. The Direct-Reading Dosimeter is designed to satisfy military specifications for the IM-Series RADIAC METER and ANSI N13.5 and N322 requirements. The metal clip attaches the dosimeter to a pocket or any object to monitor total radiation exposure. They are hermetically-sealed and immersion proof.
Availability: Commercially Available
Manufacturer |
| Arrow-Tech, Inc. |
Product Name |
| Direct Reading Pocket Dosimeters |
Detection Category |
| Radiological/Nuclear; |
Detection Principle |
| Scintillation Detectors; |
Detection Method |
| Scintillation Detectors; |
Application |
| Dosimeters; Personal Radiation Detectors; |
Product Model Number |
| W138; W138-S; W500; W500-S; W720; W725; W725-S; W730; W735; 740; 742; 746 |
Equipment Type |
| Instrument |
Product Synopsis |
| The Direct-Reading Dosimeters are designed to measure and directly read, at any time accumulated dose of gamma and x-ray radiation exposure. The Direct-Reading Dosimeter is designed to satisfy military specifications for the IM-Series RADIAC METER and ANSI N13.5 and N322 requirements. The metal clip attaches the dosimeter to a pocket or any object to monitor total radiation exposure. They are hermetically-sealed and immersion proof. |
Availability |
| Commercially Available |
Technology Readiness Level (TRL) |
| 9 |
User Feedback Sources |
| Indifferent/No user feedback |
Supporting Documentation |
| Images: direct read138.jpg; direct read746.jpg; |
Dimensions |
| 4.5 x 0.6 in (12.4 x 1.5 cm) |
Weight |
| <1 lb.; 1.0 oz (25 g) |
Power Requirements |
| None |
Transportability |
| Pocket Size |
Ruggedness |
| Extreme Temperatures/Humidity; Waterproof/Resistant; Hermetically-sealed and immersion proof. |
Operating Conditions |
| -20 to 60°C (-4 to 140°F) |
Consumables |
| None |
Suggested Routine Maintenance |
| Clean the eyepiece lens and the charging switch insulator with clean water and a cloth that is free of lint and grit. |
Expected Operational Life |
| Indefinite |
Shelf Life |
| >5 years |
Unit Cost |
| $150.00 |
Radiological Targets |
| Gamma and X-ray |
Adaptability |
| No; cannot detect or add new targets |
Sample Introduction |
| Radioactive Particle |
Sensitivity/Detection Limits |
| mR; 0 to 600 R |
Start Up Time (From Cold Start To Sample Ready) |
| Seconds |
Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
Total Run Time |
| Continuous |
Alarm Capability |
| No |
Other Operational Parameters |
| Energy range: Gamma and X-Ray 16 keV to 6 MeV |
Training Required |
| <1 hour training |
Training Available |
| No |
Manuals Available |
| Yes |
Reachback Service |
| No |
Warranties |
| 2 year |
Approved Vendors |
| Larus Systems |