Direct Read Pocket Dosimeters

The Direct-Reading Dosimeters are designed to measure and directly read, at any time accumulated dose of gamma and x-ray radiation exposure. The Direct-Reading Dosimeter is designed to satisfy military specifications for the IM-Series RADIAC METER and ANSI N13.5 and N322 requirements. The metal clip attaches the dosimeter to a pocket or any object to monitor total radiation exposure. They are hermetically-sealed and immersion proof.

Notify me on updates of this product 

Availability: Commercially Available

+1 877 477 6461
417 Main Avenue West
P.O. Box 1240 Rolla, North Dakota 58367-1240
USA
www.dosimeter.com
Manufacturer
Arrow-Tech, Inc.
Product Name
Direct Read Pocket Dosimeters
Detection Category
Radiological/Nuclear
Detection Principle
Scintillation Detectors;
Detection Method
Scintillation Detectors;
Application
Dosimeters; Personal Radiation Detectors;
Equipment Type
Instrument
Product Synopsis
The Direct-Reading Dosimeters are designed to measure and directly read, at any time accumulated dose of gamma and x-ray radiation exposure. The Direct-Reading Dosimeter is designed to satisfy military specifications for the IM-Series RADIAC METER and ANSI N13.5 and N322 requirements. The metal clip attaches the dosimeter to a pocket or any object to monitor total radiation exposure. They are hermetically-sealed and immersion proof.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
Dimensions
4.5 x 0.6 in (12.4 x 1.5 cm)
Weight
1.0 oz (25 g)
Power Requirements
None
Transportability
Pocket Size
Durability
Rugged. Hermetically-sealed and immersion proof.
Operating Conditions
-20 to 60°C (-4 to 140°F)
Calibration Schedule
Not Specified
Suggested Routine Maintenance
Clean the eyepiece lens and the charging switch insulator with clean water and a cloth that is free of lint and grit.
Expected Operational Life
Indefinite
Shelf Life
20 years
Unit Cost
$150.00
Radiological Targets
Gamma and X-ray
Customize For New Targets
No
Sample Introduction
Particle
Sensitivity/Detection Limits
0 to 600 R
Known Interferents/Inhibitors
Not Specified
Start Up Time (From Cold Start To Sample Ready)
Seconds
Response Time (Sample Application To Output)
Seconds
Total Run Time
Continuous
Alarm Capability
No
Other Operational Parameters
Energy range: Gamma and X-Ray 16 keV to 6 MeV
Operator Skills Required
Non-Technical Background
Training Available
No
Manuals Available
Yes
Reachback Service
No
Warranties
2 year
ITAR Export Regulations
Not Specified
IATA Shipping Restrictions
Not Specified
Approved Vendors
Larus Systems
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: