Lonestar Portable Analyzer

Lonestar™ Portable Analyzer is a portable chemical monitor that detects and identifies chemicals at the part-per-billion level using Field Asymmetric Ion Mobility Spectrometry (FAIMS). The product can be trained to respond to new chemicals and can be integrated with other sensors and third party systems.

Notify me on updates of this product 

Availability: Commercially Available: 30 to 60 days for delivery

Mark Brennan
Executive Vice President
mark.brennan@owlstone.com
+1 203 908 4848
761 Main Avenue
Norwalk, CT 06851
USA
www.owlstoneinc.com
Manufacturer
Owlstone, Inc.
Product Name
Lonestar Portable Analyzer
Detection Category
Chemical; Explosives
Detection Principle
Spectrometry;
Detection Method
Field Asymmetric Ion Mobility Spectrometry (FAIMS);
Application
Emergency Response; Gas Analysis; Screening; Trace Analysis;
Equipment Type
Instrument
Product Synopsis
Lonestar™ Portable Analyzer is a portable chemical monitor that detects and identifies chemicals at the part-per-billion level using Field Asymmetric Ion Mobility Spectrometry (FAIMS). The product can be trained to respond to new chemicals and can be integrated with other sensors and third party systems.
Availability
Commercially Available: 30 to 60 days for delivery
Technology Readiness Level (TRL)
9
Dimensions
15 x 10 x 7.7 in (383 × 262 × 195 mm)
Weight
3.6 lbs (7.8 kg)
Power Requirements
AC power only 120/240VAC
Transportability
Person-Portable
Durability
Rugged and transportable
Operating Conditions
Not susceptible to extreme temperatures
Consumables
Charcoal filter
Calibration Schedule
Not Specified
Suggested Routine Maintenance
Not Specified
Available Accessories
Vapor based generator
Data Analysis Support Equipment
Not Specified
Communications Interface
USB × 4. RJ45 Ethernet network connection. GPIO. Bluetooth wireless (optional)
Expected Operational Life
Not Specified
Shelf Life
10 years
Unit Cost
$50,000.00
Maintenance Cost
Not Specified
Tested For Chemical Agents
Yes
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
DNT, DMNB, RDX, TNT MNT & DNT
Number of Library Entries
Not Specified
Customize For New Targets
Yes
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppb
Known Interferents/Inhibitors
Not Specified
Start Up Time (From Cold Start To Sample Ready)
5 minutes
Response Time (Sample Application To Output)
< 1 second
Total Run Time
< 5 minutes
Alarm Capability
Audible and visual
Software Control
Yes
Operator Skills Required
Non-technical background
Training Available
1 day training included with the instrument
Manuals Available
Operator’s manual
Reachback Service
Not Specified
Warranties
1 year
ITAR Export Regulations
The Lonestar® analyzer contains a sealed 63Ni radioactive source. For the US, the product is manufactured in compliance with U.S. NRC safety criteria in 10 CFR 32.27 so the purchaser is exempt from any regulatory requirements. For transport purposes the Lonestar® complies to UN2911 standards for radioactive sources, and is provided with an identification certificate
IATA Shipping Restrictions
The Lonestar® analyzer contains a sealed 63Ni radioactive source. For the US, the product is manufactured in compliance with U.S. NRC safety criteria in 10 CFR 32.27 so the purchaser is exempt from any regulatory requirements. For transport purposes the Lonestar® complies to UN2911 standards for radioactive sources, and is provided with an identification certificate
Data File Type Format
Not Specified