MiniCAMS Series 2001/3001

The MINICAMS® Series 3001 is an automatic, near-real-time continuous air monitoring system using gas chromatography and sample collection with a solid-adsorbent preconcentrator or fixed-volume sample loop. The MINICAMS® Series 3001 is a flexible, expandable system developed specifically for the detecting all CW agents, simulants, and related compounds at levels below the U.S. Surgeon General's 8-hr Time-Weighted-Average (TWA) concentrations and at the proposed Worker Population Limits and Short-Term Exposure Limits for HD, GB, and VX.

Notify me on updates of this product 

Availability: DISCONTINUED

Greg Houston
Sales Manager
+1 205 733 6900 Ext. 204
2148 Pelhem Parkway, Building 400
Pelhem, Alabama 35124
USA
www.oico.com
Manufacturer
OI Analytical
Product Name
MiniCAMS Series 2001/3001
Detection Category
Chemical
Detection Principle
Chromatography;Sensors;
Detection Method
Gas Chromatography; Pulsed Flame Photometric Detector (PFPD);Flame Photometric Detection;
Application
Gas Analysis; Laboratory Analysis;
Equipment Type
Instrument
Product Synopsis
The MINICAMS® Series 3001 is an automatic, near-real-time continuous air monitoring system using gas chromatography and sample collection with a solid-adsorbent preconcentrator or fixed-volume sample loop. The MINICAMS® Series 3001 is a flexible, expandable system developed specifically for the detecting all CW agents, simulants, and related compounds at levels below the U.S. Surgeon General's 8-hr Time-Weighted-Average (TWA) concentrations and at the proposed Worker Population Limits and Short-Term Exposure Limits for HD, GB, and VX.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
12 x 12 x 10 in (30.5 x 30.5 x 25.4 cm)
Weight
<30 lbs.; 19.8 lbs (9 kg)
Power Requirements
AC/DC Line Power; 110 V AC 50/60 Hz (600 W)
Transportability
Mounted
Operating Conditions
0 to 40°C (32 to 104°F)
Consumables
>$1,000/year; Breathing air and high purity hydrogen required for FPD and PFPD, Helium carrier gas
Solvents/Reagents
None
Calibration Schedule
Calibrated for specific applications
Suggested Routine Maintenance
Columns, detectors, and concentrator materials
Communications Interface
RS-232, RS-485
Shelf Life
>5 years
Unit Cost
$31,125.00
Maintenance Cost
~ $2,500 or less a yr. Pre concentrator tubes are $1,330 or less for a package of 100 (lasts over a year). The V-TO-G pads are $370 for a package of 100. Support gasses Air, Hydrogen, and Nitrogen will be purchased on an as needed basis.
Tested For Chemical Agents
Yes
Tested For ITF-25 TIC/TIMs
Yes
Other Chemical Targets
Yes, petroleum products
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Start Up Time (From Cold Start To Sample Ready)
10 minutes
Response Time (Sample Application To Output)
<1 minute; Near-real-time, depends on GC programming
Alarm Capability
Yes
Software Control
Yes
Other Operational Parameters
Programmable for specific needs
Training Required
<1 week training
Training Available
2 days training for two people at facility in Birmingham, Alabama
Manuals Available
User manual
Warranties
1 year parts and labor
IATA Shipping Restrictions
Yes; Compressed gas cylinders must be shipped ground only according to IATA restrictions.
Please enter contact info.
Email Address: 
Company: 
Name: 