IonCAM

The IonCam is a compact, transportable mass spectrometer (MS) for applications in environmental analysis, process measurement, and general MS applications. IonCam is based on combination of a miniaturized, double-focusing mass spectrometer of Mattauch-Herzog geometry with a low thermal mass gas chromatograph. The IonCam is designed for analysis of vapors only.

Notify me on updates of this product 

Availability: DISCONTINUED

Greg Houston
Sales Manager
+1 205 733 6900 Ext. 204
2148 Pelham Parkway, Building 400
Pelham, AL 35124
USA
www.oico.com
Manufacturer
OI Analytical
Product Name
IonCAM
Detection Category
Chemical; Explosives
Detection Principle
Spectrometry;
Detection Method
Gas Chromatography;
Application
Emergency Response; Gas Analysis;
Equipment Type
Instrument
Product Synopsis
The IonCam is a compact, transportable mass spectrometer (MS) for applications in environmental analysis, process measurement, and general MS applications. IonCam is based on combination of a miniaturized, double-focusing mass spectrometer of Mattauch-Herzog geometry with a low thermal mass gas chromatograph. The IonCam is designed for analysis of vapors only.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
17.25 × 17 × 10 in (438 × 432 × 254 mm)
Weight
<50 lbs.; 42 lbs (19 kg)
Power Requirements
AC/DC Line Power; 24 VDC (18-36 VDC) Dual input for battery/wall
Transportability
Person-Portable
Ruggedness
Extreme Temperatures/Humidity; Not militarized, drop sensitive
Operating Conditions
–18 to 60°C (0 to 140°F)
Consumables
<$1,000/year; Carrier gas
Solvents/Reagents
None
Calibration Schedule
Calibrate for specific needs
Suggested Routine Maintenance
Replace columns
Data Analysis Support Equipment
Carrier gas
Communications Interface
USB
Shelf Life
>5 years
Unit Cost
$50,000.00
Maintenance Cost
Replacement columns, carrier gas
Tested For Chemical Agents
Yes
Tested For ITF-25 TIC/TIMs
Yes
Tested For Explosives
Yes
Other Chemical Targets
Yes
Adaptability
Yes
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
False Negative Rates
GC/MS is highly selective for volatile and semivolatile organic compounds when used by a skilled operator. Low false positive/negative rates for target analytes
Start Up Time (From Cold Start To Sample Ready)
10 minutes
Response Time (Sample Application To Output)
<1 minute; near real-time
Software Control
IonCam software IonCam Analyzer
Other Operational Parameters
1 Tesla NdFeB Magnet Electron Impact 0-130 V Mass Range: 7 to 250 amu Mass Resolution: 0.25 amu low mass to 1 amu high mass
Training Required
<1 day training
Training Available
Yes
Manuals Available
Yes
Warranties
1 year
IATA Shipping Restrictions
Yes; IATA regulations require that compressed gas cylinders must be shipped ground transport only.