IonCAM
The IonCam is a compact, transportable mass spectrometer (MS) for applications in environmental analysis, process measurement, and general MS applications. IonCam is based on combination of a miniaturized, double-focusing mass spectrometer of Mattauch-Herzog geometry with a low thermal mass gas chromatograph. The IonCam is designed for analysis of vapors only.
Availability: DISCONTINUED
Greg Houston
Sales Manager
+1 205 733 6900 Ext. 204
2148 Pelham Parkway, Building 400
Pelham, AL 35124
USA
|
|
www.oico.com
| Manufacturer |
| OI Analytical |
| Product Name |
| IonCAM |
| Detection Category |
| Chemical; Explosives |
| Detection Principle |
| Spectrometry; |
| Detection Method |
| Gas Chromatography; |
| Application |
| Emergency Response; Gas Analysis; |
| Equipment Type |
| Instrument |
| Product Synopsis |
| The IonCam is a compact, transportable mass spectrometer (MS) for applications in environmental analysis, process measurement, and general MS applications. IonCam is based on combination of a miniaturized, double-focusing mass spectrometer of Mattauch-Herzog geometry with a low thermal mass gas chromatograph. The IonCam is designed for analysis of vapors only. |
| Availability |
| DISCONTINUED |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 17.25 × 17 × 10 in (438 × 432 × 254 mm) |
| Weight |
| <50 lbs.; 42 lbs (19 kg) |
| Power Requirements |
| AC/DC Line Power; 24 VDC (18-36 VDC) Dual input for battery/wall |
| Transportability |
| Person-Portable |
| Ruggedness |
| Extreme Temperatures/Humidity; Not militarized, drop sensitive |
| Operating Conditions |
| –18 to 60°C (0 to 140°F) |
| Consumables |
| <$1,000/year; Carrier gas |
| Solvents/Reagents |
| None |
| Calibration Schedule |
| Calibrate for specific needs |
| Suggested Routine Maintenance |
| Replace columns |
| Data Analysis Support Equipment |
| Carrier gas |
| Communications Interface |
| USB |
| Shelf Life |
| >5 years |
| Unit Cost |
| $50,000.00 |
| Maintenance Cost |
| Replacement columns, carrier gas |
| Tested For Chemical Agents |
| Yes |
| Tested For ITF-25 TIC/TIMs |
| Yes |
| Tested For Explosives |
| Yes |
| Other Chemical Targets |
| Yes |
| Adaptability |
| Yes |
| Sample Introduction |
| Vapor/Gas |
| Sensitivity/Detection Limits |
| ppm |
| False Negative Rates |
| GC/MS is highly selective for volatile and semivolatile organic compounds when used by a skilled operator. Low false positive/negative rates for target analytes |
| Start Up Time (From Cold Start To Sample Ready) |
| 10 minutes |
| Response Time (Sample Application To Output) |
| <1 minute; near real-time |
| Software Control |
| IonCam software IonCam Analyzer |
| Other Operational Parameters |
| 1 Tesla NdFeB Magnet Electron Impact 0-130 V Mass Range: 7 to 250 amu Mass Resolution: 0.25 amu low mass to 1 amu high mass |
| Training Required |
| <1 day training |
| Training Available |
| Yes |
| Manuals Available |
| Yes |
| Warranties |
| 1 year |
| IATA Shipping Restrictions |
| Yes; IATA regulations require that compressed gas cylinders must be shipped ground transport only. |