6600V2
The YSI 6600 V2 data sonde measures conductivity (salinity), temperature, depth or level, pH/ORP, dissolved oxygen, turbidity, chlorophyll, and blue-green algae; the V2-2 measures two of the four parameters simultaneously. Additional calculated parameters include total dissolved solids, resistivity, and specific conductance. Utilize YSI’s new optical sensor design and anti-fouling wiper control for improved reliability during extended deployments
Availability: Commercially Available
| Manufacturer |
| YSI, Inc. |
| Product Name |
| 6600V2 |
| Detection Category |
| Chemical |
| Detection Principle |
| Sensors; |
| Detection Method |
| Electrochemical Detection ; |
| Application |
| Water Quality; |
| Equipment Type |
| Sensor |
| Product Synopsis |
| The YSI 6600 V2 data sonde measures conductivity (salinity), temperature, depth or level, pH/ORP, dissolved oxygen, turbidity, chlorophyll, and blue-green algae; the V2-2 measures two of the four parameters simultaneously. Additional calculated parameters include total dissolved solids, resistivity, and specific conductance. Utilize YSI’s new optical sensor design and anti-fouling wiper control for improved reliability during extended deployments |
| Availability |
| Commercially Available |
| Technology Readiness Level (TRL) |
| 9 |
| User Feedback Sources |
| Indifferent/No user feedback |
| Dimensions |
| 3.5 x 21.6 in (89 x 549 mm) |
| Weight |
| <30 lbs.; 7 lbs (3.2 kg) |
| Power Requirements |
| AC/DC Line Power; Alkaline Battery; External 12 V DC Internal 8 C-size alkaline batteries |
| Transportability |
| Handheld |
| Operating Conditions |
| Medium: Fresh, Sea, or Polluted Water -5 to 50°C Operating Temperature -10 to 60°C Storage Temperature |
| Consumables |
| >$1,000/year; Calibration cup, calibration solutions, buffers, DO membranes, sensors |
| Calibration Schedule |
| Yes |
| Available Accessories |
| Flow cell, wipe kits, carrying case |
| Communications Interface |
| RS-232 and SDI-12 |
| Other Chemical Targets |
| Measures: Dissolved Oxygen, Conductivity, Salinity, Temperature, pH, Turbidity, Nitrate, Ammonia, Chloride, Rhodamine |
| Sample Introduction |
| Liquid |
| Sensitivity/Detection Limits |
| mg; DO range 0-50 mg/L with resolution of 0.01 mg/L Conductivity range 0-100mD/cm with resolution of 0.001 mS/cm Salinity range 0-70 ppt with resolution of 0.01 ppt Turbidity range of 0-1000 NTU with resolution of 0.1 NTU Nitrate range of 0-200 mg/L with resolution of 0.001 mg/L Ammonia range of 0-200 mg/L with resolution of 0.001 mg/L Chloride range of 0-1000 mg/L with resolution of 0.001 mg/L Rhodamine range of 0-200 mg/L with resolution of 0.001 mg/L |
| Response Time (Sample Application To Output) |
| Continuous (<30 seconds) |
| Software Control |
| PC |
| Training Required |
| <1 day training |
| Manuals Available |
| Yes |
| Warranties |
| 1 year instrument and electrode |