5100

The YSI Model 5100 is the same as the 5000, except it also has automated and application specific features, such as built-in application software for the calculation of Oxygen Uptake Rate (OUR) and Specific Oxygen Uptake Rate (SOUR). A base unit which operates with sensors YSI 5010 BOD Probes or YSI 5905 BOD probes with the 5011 adapter. The base unit converts the probe signal into a useful reading. The reading is displayed and may also be stored on the unit or transferred via RS-232 to a computer.

Notify me on updates of this product 

Availability: Commercially Available

environmental@ysi.com
+1 937 767 7241
1700/1725 Brannum Lane
Yellow Springs, OH 45387
USA
www.ysi.com
Manufacturer
YSI, Inc.
Product Name
5100
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Sensors
Application
Water Quality;
Equipment Type
Sensor
Product Synopsis
The YSI Model 5100 is the same as the 5000, except it also has automated and application specific features, such as built-in application software for the calculation of Oxygen Uptake Rate (OUR) and Specific Oxygen Uptake Rate (SOUR). A base unit which operates with sensors YSI 5010 BOD Probes or YSI 5905 BOD probes with the 5011 adapter. The base unit converts the probe signal into a useful reading. The reading is displayed and may also be stored on the unit or transferred via RS-232 to a computer.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
9 x 9.5 x 4.4 in (229 x 242 x 112 mm)
Weight
<5 lbs.; 2.6 lbs (1.2 kg)
Power Requirements
AC/DC Line Power; Alkaline Battery; AC adapter or 4 C-size alkaline batteries
Transportability
Handheld
Operating Conditions
0 to 45°C (operating temperature) 10 – 90% relative humidity, non-condensing (operating)
Calibration Schedule
Yes
Data Analysis Support Equipment
The 5100 is compatible with BOD Analyst Software, using RS-232 interface
Communications Interface
RS-232
Unit Cost
$1,625.00
Maintenance Cost
Probe $650, membrane $56
Other Chemical Targets
Measures Dissolved Oxygen, Temperature, Pressure
Sample Introduction
Liquid
Sensitivity/Detection Limits
ppm; %; 10.0 to 600.0% air saturation, 0.0 to 60.0 mg/L, 0 to 1500 dissolved oxygen
Start Up Time (From Cold Start To Sample Ready)
15 minutes
Response Time (Sample Application To Output)
<5 minutes; ~2 minutes, (allowing for equilibration of the sensor in sample)
Software Control
PC
Training Required
<1 day training
Manuals Available
Yes
Warranties
2 year instrument, 1 year probe