Model 2166 5% Carbon Dioxide Monitor

Same as the Model 2156, except this one comes with a pump. The Model 2166 is a non-dispersive infrared gas monitor designed as a fully functioning stand-alone unit for the continuous monitoring of carbon dioxide. The optical system is not affected by humidity. The pumped gas sampling circuit has a self-draining water trap. This eliminates difficulties with water condensation in the sample lines. It has a 0.56 inch high digital readout and two adjustable levels detect circuits with associated front panel indicators (yellow and red) and SPDT relay contacts. Models are also available to monitor .3, .5, 1.0, 1.5, 2.0, and 3% carbon dioxide.

Notify me on updates of this product 

Availability: Commercially Available

Bill Dunlap
vti@val-tronics.com
+1 209 754 0707
3463 Double Springs Rd
Valley Springs, CA 95252
www.val-tronics.com/contact.html
Manufacturer
VTI-Valtronics, Inc.
Product Name
Model 2166 5% Carbon Dioxide Monitor
Detection Category
Chemical
Detection Principle
Molecular Spectroscopy;
Detection Method
Non-Dispersive Infrared (NDIR);
Application
Gas Analysis;
Equipment Type
Sensor
Product Synopsis
Same as the Model 2156, except this one comes with a pump. The Model 2166 is a non-dispersive infrared gas monitor designed as a fully functioning stand-alone unit for the continuous monitoring of carbon dioxide. The optical system is not affected by humidity. The pumped gas sampling circuit has a self-draining water trap. This eliminates difficulties with water condensation in the sample lines. It has a 0.56 inch high digital readout and two adjustable levels detect circuits with associated front panel indicators (yellow and red) and SPDT relay contacts. Models are also available to monitor .3, .5, 1.0, 1.5, 2.0, and 3% carbon dioxide.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
13 x 7.5 x 5 in (331 x 191 x 127 mm)
Weight
<30 lbs.; <6 lbs. (2.72 kg)
Power Requirements
AC/DC Line Power; 115/220 VAC, 50/60 Hz
Transportability
Pocket Size
Operating Conditions
0 to 50°C (operating temperature) -40 to 70°C (storage temperature) 5 – 95% Relative Humidity, non-condensing
Consumables
<$1,000/year; Calibration kit $631.00
Calibration Schedule
Yes, every 6 months
Suggested Routine Maintenance
Rarely
Available Accessories
Model 2166 gas calibration, hydrophobic filter
Communications Interface
0-5 V and 4-20 mA outputs
Shelf Life
>5 years
Unit Cost
$3,103.00
Maintenance Cost
~$200, infrequently needed
Other Chemical Targets
Carbon dioxide
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm; %
Start Up Time (From Cold Start To Sample Ready)
30 to 60 seconds
Response Time (Sample Application To Output)
Continuous (<30 seconds); <10 seconds
Alarm Capability
Audio alarm, and yellow “set point” indicator lights
Training Required
<1 week training
Manuals Available
User Manual
Warranties
1 yr
Please enter contact info.
Email Address: 
Company: 
Name: 
Title: