Ceeker

Current system is based on the excitation/emission profile of DPA, a spore-specific compound. As such, the current design does not discriminate among spores produced by different microbial species (i.e., cannot discriminate B. anthracis from B. thuringiensis). However, excitation and emission profiles employed for identification may be expanded beyond the DPA signature to detect other microbes, including non-spore formers. The system is hand-held and designed for use by first responders.

Notify me on updates of this product 

Availability: DISCONTINUED

+64 3372 3506
190 Hereford Street, P.O. Box 13769
Christchurch 8141
New Zealand
www.veritide.com
Manufacturer
Veritide
Product Name
Ceeker
Detection Category
Biological
Detection Principle
Molecular; Molecular Spectroscopy;
Detection Method
Lateral Flow Hand Held Immunoassay; Fluorescence;
Application
Detection;
Equipment Type
Instrument
Product Synopsis
Current system is based on the excitation/emission profile of DPA, a spore-specific compound. As such, the current design does not discriminate among spores produced by different microbial species (i.e., cannot discriminate B. anthracis from B. thuringiensis). However, excitation and emission profiles employed for identification may be expanded beyond the DPA signature to detect other microbes, including non-spore formers. The system is hand-held and designed for use by first responders.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
11 x 8.5 x 4.5 in (280 x 216 x 115 mm)
Weight
<5 lbs.; 4.4 lbs (2 kg)
Power Requirements
Lithium Battery
Transportability
Handheld
Operating Conditions
14 to 140 °F
Tested For Biological Agents
Anthrax Spores
Adaptability
Yes; manufacturer can add new targets to detector
Sample Introduction
Vapor/Gas; Solid
Sensitivity/Detection Limits
3,000 spores
Known Interferents/Inhibitors
Reportedly able to detect spores in presence of potential masking or interfering substances including flour, baking powder, talcum powder, and dust. In-house tests of excitation/emission profile based systems are consistent with those reports.
Start Up Time (From Cold Start To Sample Ready)
8 Minutes
Response Time (Sample Application To Output)
<15 minutes; 3-10 Minutes
Alarm Capability
Graphical display and audible response
Other Operational Parameters
Non-destructive optical analysis using ultraviolet light and in-line optical recognition software with detection algorithms to identify potentially lethal anthrax spores in powder samples; chemical biodetection
Training Required
<1 day training