XL3t900

Discontinued: The Thermo Scientific Niton XL3t is a tube-based handheld x-ray fluorescence (XRF) analyzer. The XL3t allows for light element analysis with an attachable helium purge system.

Notify me on updates of this product 

Availability: DISCONTINUED

+1 978 642 1132
46 Jonspin Road
Wilmington, MA 01887
USA
www.thermoscientific.com
Manufacturer
Thermo Fisher Scientific, Inc.
Product Name
XL3t900
Detection Category
Chemical
Detection Principle
Elemental Analysis;
Detection Method
X-ray Fluorescence;
Application
Laboratory Analysis; Forensics;
Equipment Type
Instrument
Product Synopsis
Discontinued: The Thermo Scientific Niton XL3t is a tube-based handheld x-ray fluorescence (XRF) analyzer. The XL3t allows for light element analysis with an attachable helium purge system.
Availability
DISCONTINUED
Technology Readiness Level (TRL)
9
User Feedback Sources
Hands-on experience, DoD
Dimensions
9.60 x 9.05 x 3.75 in (244 x 230 x 95.5 mm)
Weight
<5 Lbs.; < 3.0 Lbs. (< 1.3 kg)
Power Requirements
Lithium Battery; Two 4 (or optional 6) cell lithium-ion battery packs
Transportability
Handheld
Ruggedness
None; Must be handled carefully, unit has a drop sensor
Operating Conditions
Avoid extreme temperatures and high humidity
Consumables
<$1,000/year
Calibration Schedule
Yes
Available Accessories
Optional: Portable test stand, stationary test stand, extension pole with tripod stand, welding mask, HotFoot™ hot surface adapter, soil testing guard, internal CCD sample imaging system, variable spot size aperture.
Data Analysis Support Equipment
Portable test stand, stationary test stand, tripod stand Extension pole Welding mask HotFoot™ hot surface adapter Soil testing guard Internal CCD sample imaging system Variable spot size aperture Mining Kit
Communications Interface
USB, Bluetooth and RS-232 serial communication
Expected Operational Life
Indefinite
Shelf Life
>5 years
Unit Cost
$77,495.00
Other Chemical Targets
Programmed to detect elements Mg-U
Adaptability
Yes; manufacturer can add new targets to detector
Sample Introduction
Liquid; Solid
Sensitivity/Detection Limits
ppm
Start Up Time (From Cold Start To Sample Ready)
2 minutes
Response Time (Sample Application To Output)
<5 minutes; 5 to 120 seconds
Alarm Capability
Visual
Software Control
Yes
Other Operational Parameters
Multiple modes for analysis
Training Required
<1 day training
Training Available
Yes
Manuals Available
User manual
Warranties
1 year
IATA Shipping Restrictions
Yes; Compressed gas cylinders must be shipped ground only according to IATA restrictions.