Oxymat 6

Paramagnetic. The measuring cell has a cylindrical zinc oxide membrane. The sample gas flows through the sensor at a constant rate and at 650°C. One side of the sensor is exposed to air. The zinc oxide membrane is coated with platinum on both sides. Ions migrate to the side with the lower partial pressure. The gradient of ions produced across the membrane thickness leads to a difference in potential.

Notify me on updates of this product 

Availability: Commercially Available

Stuart Hunter
Technical
+1 713 939 3202
One Internet Plaza
Johnson City, TN 37604-1663
USA
Manufacturer
Siemens Johnson City (SIAC)
Product Name
Oxymat 6
Detection Category
Chemical
Detection Principle
Sensors;
Detection Method
Paramagnetic Alternating Pressure Principle;
Application
Gas Analysis;
Equipment Type
Sensor
Product Synopsis
Paramagnetic. The measuring cell has a cylindrical zinc oxide membrane. The sample gas flows through the sensor at a constant rate and at 650°C. One side of the sensor is exposed to air. The zinc oxide membrane is coated with platinum on both sides. Ions migrate to the side with the lower partial pressure. The gradient of ions produced across the membrane thickness leads to a difference in potential.
Availability
Commercially Available
Technology Readiness Level (TRL)
9
User Feedback Sources
Indifferent/No user feedback
Dimensions
19 x 14 x 6.97 in (483 x 355 x 178 mm)
Weight
>50 lbs.; 11 kg, Field mount weighs 50-55 lbs, rack mount weighs 30-35 lbs
Power Requirements
AC/DC Line Power; 100 to 120 V AC (rated range of use 90 V to 132 V) 48-63 Hz 200 to 240 V AC (rated range of use 180 V to 264 V) 48-63 Hz
Transportability
Benchtop/Fixed
Ruggedness
Extreme Temperatures/Humidity; Not designed for rough handling or moist weather
Operating Conditions
-40 to 70°C (storage and transport temperature) 5 to 45°C (operation temperature) <90% relative humidity (must not fall below dew point)
Consumables
<$1,000/year; Calibration gas, nitrogen (for a reference gas), sample pump
Calibration Schedule
Yes
Data Analysis Support Equipment
Filter and compressor/cooler
Communications Interface
RS 485
Unit Cost
$11,000.00
Maintenance Cost
Minimal
Other Chemical Targets
Measures oxygen only
Sample Introduction
Vapor/Gas
Sensitivity/Detection Limits
ppm
Start Up Time (From Cold Start To Sample Ready)
At room temp < 30 minutes, maximum accuracy after about 3 hours
Response Time (Sample Application To Output)
Continuous (<30 seconds); ~ 10 seconds
Alarm Capability
Yes, alarms are programmable
Training Required
<1 week training
Training Available
Yes
Manuals Available
Yes
Warranties
18 month